Agilent Technologies J&W GC/MS Columns

Agilent J&W GC/MS columns are highly efficient, inert
and bleed less than the competition, offering you uncompromised sensitivity. When used in conjunction with an optimized GC/MS system, these columns achieve the lowest possible detection limits for your most difficult analytes with excellent mass spectral clarity. Increased analytical sensitivity with resulting lower detection limits is a function of the ratio of signal-to-noise. Improvements to signal-to-noise are achieved by:


Agilent 6890 GC-MS

Increasing signal -
Highly efficient, inertGC/MS columns produce narrow and tall peaks for the most active analytes.

Decreasing noise -
Low column bleed reduces baseline rise and the amount of noise contributed by the column, thereby reducing baseline interference.

 
DB-1ms: Very low bleed characteristics, general purpose
HP-1ms: Very low bleed characteristics, general purpose
DB-5ms: Very low bleed characteristics, general purpose
HP-5ms: Very low bleed characteristics, general purpose
DB-XLB: Low polarity, unique selectivity
DB-35ms: Mid Polarity, Ideal for confirmational analyses
DB-17ms: Mid Polarity, best column for CLP pesticides
DB-225ms: Mid/high polarity
Ultra Inert: Even lower bleeding characteristics!!
DuraGuard: Different phases with "build in" guard column
 
DuraGuard
 
  • Columns with “built in“ guard columns, no press-fit connectors
  • Minimize front-end contamination and increase column lifetime
  • Aid in focusing sample onto the front of the column for better peak shape
  • Minimize MSD contamination originating from the column (when used in transfer line)
 

DuraGuard columns of different phases and dimensions are available through Agilent Technologies' custom column shop. Any DB polysiloxane or low bleed phase can be made as a DuraGuard column with 0.18 mm ID or larger fused silica tubing. Ask for a custom column quote (part number 100-2000 and specify the phase, ID, length, and film thickness of analytical column, and desired length of DuraGuard).

 
 Phase    ID (mm)    Length (m)    Film (μm)    DRGD Length (m)    Part No.  
           
 DB-1    0.25    30    0.25   10  
122-1032G
 DB-XLB    0.25    30    0.25   10  
122-1232G
 DB-5.625    0.25    30    0.25   5  
122-5631G5
 DB-5ms    0.25    30    0.25   10  
122-5532G
 DB-5ms    0.25    30    0.50   10  
122-5536G
 DB-5ms    0.25    60    0.25   10  
122-5562G
 DB-5ms    0.32    30    1.00   10  
122-5533G
 DB-5ms    0.32    30    1.00   10  
123-5533G
 DB-5ms    0.53    30    0.50   10  
125-5537G
 DB-1701    0.53    30    1.00   10  
125-0732G
 DB-624    0.53    30    3.00    5  
125-1334G5
 

 


 
 