Agilent Technologies J&W High Temperature GC Columns

Resistant to damage under extreme operating conditions, DB-1ht, DB5ht, DB17ht columns allows users to analyze samples at temperatures up to 450ºC. Based on SS capillary, it addresses several problems associated with fused silica columns. Column can be used for separation of high boiling mixtures such as long chain hydrocarbons, polymers, plastics, waxes, heavy polyaromatic hydrocarbons, tars, triglycerides, motor oils, surfactants, and crown ethers.

High temperature GC, crown ether

 
2-Aminomethyl-15-crown-5
 
DB-1ht
 
  • 100% Dimethylpolysiloxane
  • Non-polar
  • Specially processed for extended temperature limit of 400°C
  • High temperature, polyimide-coated, fused silica tubing
  • Excellent peak shape and faster elution times for high boilers
  • Bonded and cross-linked
  • Solvent rinsable
 
Similar Phases: Stx-1ht
 
ID (mm)   Length (m)   Film (μm)   Temp Limits (°C)   Part No.  
         
0.25   15   0.10   -60 to 400  
122-1111
0.25   30   0.10   -60 to 400  
122-1131
0.32   15   0.10   -60 to 400  
123-1111
0.32   30   0.10   -60 to 400  
123-1131
 
DB-5ht
 
  • (5%-Phenyl)-methylpolysiloxane
  • Non-polar
  • Specially processed for extended temperature limit of 400°C
  • High temperature, polyimide-coated, fused silica tubing
  • Excellent peak shape and faster elution times for high boilers
  • Bonded and cross-linked
  • Solvent rinsable
 
Similar Phases: HT5, Stx-5ht
 
ID (mm)   Length (m)   Film (μm)   Temp Limits (°C)   Part No.  
         
0.25   15   0.10   -60 to 400  
122-5711
0.25   30   0.10   -60 to 400  
122-5731
0.32   15   0.10   -60 to 400  
123-5711
0.32   30   0.10   -60 to 400  
123-5731
 
DB-17ht
 
  • (50%-Phenyl)-methylpolysiloxane
  • Midpolarity
  • Extended upper temperature limit of 365°C
  • High temperature, polyimide-coated, fused silica tubing
  • Excellent peak shape and faster elution times for high boilers
  • Improved resolution for triglycerides
  • Ideal for confirmational analyses
  • Bonded and cross-linked
  • Solvent rinsable
 
Similar Phases: Rtx-65TG, BPX50, CP-TAP CB
 
ID (mm)   Length (m)   Film (μm)   Temp Limits (°C)   Part No.  
         
0.25   15   0.15   40 to 340/365  
122-1811
0.25   30   0.15   40 to 340/365  
122-1831
0.32   15   0.15   40 to 340/365  
123-1811
0.32   30   0.15   40 to 340/365  
123-1831
0.32   60   0.15   40 to 340/365  
123-1861
 