Crawford Scientific
Javascript DHTML Drop Down Menu Powered by dhtml-menu-builder.com
 
  Product Information
  Parts and Pricing
you’re in > Products > Manufacturers > Agilent Technologies > GC columns > Specialty Columns > Life Sciences
 

Agilent J&W Life Sciences

The life sciences offer some difficult challenges to capillary GC chromatographers. These include complex sample matrices, the necessity for low level detection and the chemically active characteristics of many of the samples. In response to this, Agilent offers a line of columns which are designed specifically for drugs of abuse testing.

Blood Analysis, alcohol

 
Ethanol
 
 

DB-ALC1 and DB-ALC2

 
  • Reliable blood alcohol analysis
  • Optimized primary and confirmation column pair for U.S. blood alcohol analysis
  • Faster GC run times
  • Improved resolution of key ethanol/acetone peaks
  • Available in 0.32 and 0.53 mm ID
  • Bonded and cross-linked
 
Similar Phases: Rtx-BAC1, Rtx-BAC2
 
 Description    ID (mm)    Length (m)    Film (μm)    Temp Limits   (°C)    Part No.  
           
 DB-ALC1    0.32    30    1.80    20 to 260/280  
123-9134
 DB-ALC1    0.53    30    3.00    20 to 260/280  
125-9134
 DB-ALC2    0.32    30    1.20    20 to 260/280  
123-9234
 DB-ALC2    0.53    30    2.00    20 to 260/280  
125-9234
 

HP-Blood Alcohol

 
  • Reliable blood alcohol analysis
  • Excellent confirmation column with DB-ALC2
    for method using t-butanol as internal standard
 
ID (mm)   Length (m)   Film (μm)   Temp Limits (°C)   Part No.  
         
0.32  7.5  20.00  -60 to 270/290  
190091S-510
 

DB-5ms EVDX

 
  • Specially configured and tested for drugs of abuse confirmation
  • Drug test mix included: caffeine, gluthethimide, lidocaine, phenobarbital,
    EDDP, methaqualone, methadone, cocaine, desiprmine, carbamazepine
  • DB-5ms EVDX is equivalent to (5%-Phenyl)-methylpolysiloxane
  • Consistent retention and peak shape
  • Low bleed for GC/MS analysis
  • Bonded and cross-linked
  • Solvent rinsable
 
ID (mm)   Length (m)   Film (μm)   Temp Limits (°C)   Part No.  
         
0.20 25 0.33 -60 to 325/350
128-8522
 

HP-Fast Residual Solvent

 
  • Equivalent to USP Phase G43
  • Thinner film reduces run time by 2.5 times and increases Minimum Detection Limit (MDL)
    by 2 times compared to standard film thickness used for this method
  • Bonded and cross-linked
 
Similar Phases: DB-624, PE-624, 007-624, 007-502, CP-624, ZB-624
 
ID (mm)   Length (m)   Film (μm)   Temp Limits (°C)   Part No.  
         
0.53  30  1.00    -20 to 260  
19095V-420
 
 

top


 
 