Columns Examples of application
   

Carbowax 20M and HP-20M

CAM

DX-1, DX-3 and DX-4

SE-30 and SE-54


Phase 16

Amine Analysis

EPA Method 504

 
Carbowax 20M and HP-20M
 
  • Polyethylene glycol, MW 20,000
  • Equivalent to USP Phase G16

 

 

 
Because the Carbowax 20M and the HP-20M are not bonded or cross-linked, we do not
recommend solvent rinsing. DB-WAX is the recommended bonded alternate for the HP-20M.
 

Similar Phases: DB-WAX, HP-INNOWax, DB-WAXetr

 
ID (mm)   Length (m)   Film (μm)   Temp Limits (°C)   Part No.  
Carbowax 20M
 0.25    30    0.25    60 to 220/240  
112-2032
 0.32    30    0.25    60 to 220/240  
113-2032
HP-20M
 0.20    25    0.10    60 to 220  
19091W-102
 0.20    50    0.10    60 to 220  
19091W-105
 0.32    25    0.30    60 to 220  
19091W-012
 0.32    50    0.30    60 to 220  
19091W-015
 0.53    10    1.33    60 to 220  
19095W-121
 0.53    30    1.33    60 to 220  
19095W-123
 

CAM

 
  • Base deactivated polyethylene glycol
  • Specifically designed for amine analysis
  • Excellent peak shape for primary amines
  • Replaces HP-Basicwax

 

  

 

Similar Phases: Stabilwax-DB, Carbowax Amine

 
ID (mm)   Length (m)   Film (μm)   Temp Limits (°C)   Part No.  
         
 0.25    15    0.25    60 to 220/240  
112-2112
 0.25    30    0.25    60 to 220/240  
112-2132
 0.25    30    0.50    60 to 220/240  
112-2133
 0.25    60    0.25    60 to 220/240  
112-2162
 0.32    30    0.25    60 to 220/240  
113-2132
 0.32    30    0.50    60 to 220/240  
113-2133
 0.53    30    1.00    60 to 200/220  
115-2132
 

DX-1, DX-3 and DX-4

 
  • DX-1: 90% Dimethylpolysiloxane - 10% Polyethylene Glycol
  • DX-3: (50% Dimethylpolysiloxane)(50% Polyethylene Glycol)
  • DX-4: 15% Dimethylpolysiloxane - 85% Polyethylene Glycol

 

  

 
Because DX series GC columns are not bonded and cross-linked, we do not recommend solvent rinsing.
 
ID (mm)   Length (m)   Film (μm)   Temp Limits (°C)   Part No.  
DX-1
 0.32    30    0.25    50 to 250/270  
100-2000
 0.32    30    1.00    50 to 250/270  
123-6133
 0.32    60    0.25    50 to 250/270  
100-2000
DX-3
 0.25   15  0.25    50 to 250/270  
100-2000
 0.25   30   0.25    50 to 250/270  
100-2000
 0.32   30    0.25    50 to 250/270  
100-2000
DX-4
 0.25    30    0.25    50 to 250/270  
122-6432
 0.25    60    0.25    50 to 250/270  
122-6462
 0.32    15    0.25    50 to 250/270  
123-6412
 0.32    30    0.25    50 to 250/270  
123-6432
 0.32    60    0.25    50 to 250/270  
123-6462
 

SE-30 and SE-54

 
  • SE-30: 100% Dimethylpolysiloxane
  • SE-54: (5%-Phenyl)(1%-Vinyl)-methylpolysiloxane

 

  

 
Because SE series GC columns are not bonded and cross-linked, we do not recommend solvent rinsing.
 
ID (mm)   Length (m)   Film (μm)   Temp Limits (°C)   Part No.  
SE-30
 0.32    30    0.25    0 to 325/350  
113-3032
SE-54
 0.25    30    0.25    0 to 325/350  
112-5432
 0.25    60    0.25    0 to 325/350  
112-5462
 0.32    30    0.25    0 to 325/350  
113-5432
 

 
 
©Crawford Scientific 2010