Agilent Technologies J&W Petroleum

Petroleum applications vary greatly in character. From the noble gases to simulated distillation. Agilent offers a broad range of columns designed to meet the needs of the petroleum/petrochemical chromatographer. Refer to the PLOT column section for columns for the analysis of light gases.

Octane
 
Octane
 
 
DB-2887
 
  • 100% Dimethylpolysiloxane
  • Specifically designed for simulated distillation using ASTM Method D2887
  • Rapid conditioning, fast run time and low bleed when compared to packed columns
  • Bonded and cross-linked
  • Solvent rinsable
 
Similar Phases: HP-1, Petrocol EX2887, MXT-2887, MXT-1
 
ID (mm)   Length (m)   Film (μm)   Temp Limits (°C)   Part No.  
         
0.53   10   3.00   -60 to 350  
125-2814
 
DB-HT SimDis
 
  • 100% dimethylpolysiloxane
  • “Boiling point” phase for high temperature simulated distillation
  • Durable stainless steel tubing
  • 430ºC upper temperature limit
  • Distillation range of C6 to C110+
  • Low bleed – even at 430ºC!
  • Bonded and cross-linked
  • Solvent rinsable
 
Similar Phases:
Petrocol EX2887, CP-SimDist Ultimetal, MXT-2887,
Rtx-2887, AC Controls High Temp Sim Dist, AT-2887
 
ID (mm)   Length (m)   Film (μm)   Temp Limits (°C)   Part No.  
         
0.53   5   0.15   -60 to 400/430  
145-1001
 
HP-PONA
 
  • 100% Dimethylpolysiloxane
  • Configured for the analysis of petroleum process products
  • Tested to ensure the resolution of m-xylene from p-xylene and of cyclopentane
    from 2,3-dimethylbutane
  • PONA, PIANO
  • High resolution
  • Bonded and cross-linked
  • Solvent rinsable
 

Similar Phases: Petrocol DH, SPB-1, 007-1, Rtx-1, MXT-1

Note: 100 psi regulator required to reach optimum carrier gas velocity

 
 Description    ID (mm)    Length (m)    Film (μm)    Temp Limits (°C)    Part No.  
           
 HP-PONA    0.20    50    0.50    -60 to 325/350  
19091S-001
 HP-1    0.20    50    0.50    -60 to 325/350  
19091Z-205
 HP-1    0.25    100    0.50    -60 to 325/350  
19091Z-530
 
DB-Petro
 
  • 100% Dimethylpolysiloxane
  • Configured for the analysis of petroleum process products
  • PONA, PIANO
  • High resolution
  • Bonded and cross-linked
  • Solvent rinsable
 

Similar Phases: Petrocol DH, HP-PONA, SPB-1, 007-1, Rtx-1, MXT-1

Note: 100 psi regulator required to reach optimum carrier gas velocity

 
 ID (mm)    Length (m)    Film (μm)    Temp Limits (°C)    Part No.  
         
 0.20    50    0.50    -60 to 325/350  
128-1056
 0.20    100   0.50    -60 to 325/350  
122-10A6
 
HP-1 Aluminum Clad
 
  • 100% Dimethylpolysiloxane
  • Aluminum clad fused silica tubing
  • For high temperature simulated distillation
  • Bonded and cross-linked
  • Solvent rinsable
 

Similar Phases: N/A

 
 ID (mm)    Length (m)    Film (μm)    Temp Limits (°C)    Part No.  
         
 0.53    5    0.09    -60 to 350/450  
19095S-205
 10   0.09    -60 to 350/450  
19095S-200
 
 
 

 
 