Crawford Scientific
Javascript DHTML Drop Down Menu Powered by dhtml-menu-builder.com
 
  Product Information
  Parts and Pricing
you’re in > Products > Agilent Technologies > BioAnalysis > MARS > LC Human 14
 

Multiple Affinity Removal LC Column - Human 14

 

Simple method removes 14 abundant proteins

In order to more easily isolate and identify proteins in human serum, the Agilent Human 14 Multiple Affinity Removal Column is designed to chromatographically remove fourteen interfering high-abundant proteins from human plasma samples. Removal of these abundant proteins improves the subsequent LC/MS and electrophoretic analysis of the serum sample by effectively expanding the dynamic range of the analysis.

  • Column eliminates approximately 94% of total protein (albumin, IgG, antitrypsin, IgA, transferrin, haptoglobin, fibrinogen, alpha2-macroglobulin, alpha1-acid glycoprotein, IgM, apolipoprotein Al, apolipoprotein All, complement C3, and transthyretin) when used with the Multiple Affinity Removal System.
  • Three column dimensions are available and include 4.6 x 50 mm, 4.6 x 100 mm, and 10 x 100 mm. Custom sizes and spin cartridges are also available.
  • Serum injection volume ranges between 20 - 40 µL per run for the 4.6 mm ID, and 160 µL for the 10 mm ID column.
  • Optimize sample recovery by utilizing our rapid, single injection protocols and optimized buffers.
  • Optimized 2 buffer system allows for highly reproducible re-use of the Columns for over 200 injections – available in a convenient Column Reagent Starter Kit
  • Process up to 8,000 µL of plasma/serum over the column lifetime for the 4.6 mm ID columns and 32,000 µL for the 10 mm ID columns.
  • Protocols and columns are optimized for use with human physiological samples. Column not recommended for use with mouse serum.
  • Column is compatible with most FPLC or HPLC pumps or instruments, including the Agilent 1200/1100 instruments.
 
Description Size (mm) Part Number
     
Multiple Affinity Removal Column, Hu-14 4.6 x 50
5188-6557
Multiple Affinity Removal Column, Hu-14 4.6 x 100
5188-6558
Multiple Affinity Removal Column, Hu-14 10 x 100
5188-6559
 
LC Column Specifications - Human 14
Feature Specification
   
Column Dimensions 4.6 x 50 mm (0.83 mL bed volume)
4.6 x 100 mm (1.66 mL bed volume)
10 x 100 mm (7.8 mL bed volume)
Custom sizes available
Column body material PEEK (polyetheretherketone)
End-Fitting material PEEK with 2 µm frits
Column capacity**

High-capacity serum load - 4.6 mm ID

  • 50 mm column
    Hu-14: 20 µL
  • 100 mm column
    Hu-14: 40 µL

High-capacity serum load - 10 mm ID

  • 100 mm column
    Hu-14: 250 µL
Injections/Column Standard & High-capacity > 200
Total serum/plasma processed per lifetime

High-capacity serum load - 4.6 mm ID

  • 50 mm column
    Hu-14: 4,000 µL
  • 100 mm column
    Hu-14: 8,000 µL

High-capacity serum load - 10 mm ID

  • 100 mm column
    Hu-14: 32,000 µL
Max. pressure 120 bar
Operating temperature 18 - 25oC
Column packing material Affinity resin
Immobilized ligands Affinity ligands to human high abundant proteins (albumin, IgG, antitrypsin, IgA, transferrin, haptoglobin, fibrinogen, alpha2-macroglobulin, alpha1-acid glycoprotein, IgM, apolipoprotein AI, apolipoprotein AII, complement C3 and transthyretin)
Flow rate range 0.125 - 3.0 mL/min
Shipping solution Buffer A with 0.02% sodium azide
Shipping temperature 2 - 8oC - (35 -46oF)
Storage temperature 2 - 8oC - (35 -46oF)
**For exact column capacity, consult your column certificate of analysis. Human and mouse sera protein concentrations can vary; injected sample sizes should be adjusted accordingly. Mouse serum capacities were determined using pooled Swiss Webster mouse serum.

 

 


 
 
©Crawford Scientific 2010