Crawford Scientific
Javascript DHTML Drop Down Menu Powered by dhtml-menu-builder.com
 
  Product Information
  Parts and Pricing
you’re in > Products > Agilent Technologies > BioAnalysis > MARS > LC Human 7
 

Multiple Affinity Removal LC Column - Human 7

 

Simple method removes 7 abundant proteins

The Multiple Affinity Removal LC Column – Human 7 is designed to chromatographically remove SEVEN interfering high-abundant proteins from human plasma samples. Removal of these abundant proteins improves the subsequent LC/MS and electrophoretic analysis of the serum sample by effectively expanding the dynamic range of the analysis.

  • Column eliminates approximately 88-92% of total protein (albumin, IgG, IgA, transferrin, haptoglobin, antitrypsin, and fibrinogen) when used with the Multiple Affinity Removal System
  • Three column dimensions include 4.6 x 50 mm, 4.6 x 100 mm,
    10 x 100 mm. Custom sizes also available.
  • Serum injection volume ranges between 30 - 70 µL per run for the 4.6 mm ID, and 250 - 300 µL for the 10 mm ID column
  • Optimize sample recovery by utilizing our rapid, single injection protocols and optimized buffers
  • Columns designed for over 200 injections
  • Process the most plasma/serum over the column lifetime, up to 14,000 µL for the 4.6 mm ID columns and 60,000 µL for the 10 mm ID column.
  • Protocols and column are optimized for use with human physiological samples. Column not recommended for use with mouse serum.
  • Column is compatible with most LC or HPLC pumps or instruments
 
Description Size (mm) Part Number
     
Multiple Affinity Removal Column, Hu-7 4.6 x 50
5188-6409
Multiple Affinity Removal Column, Hu-7 4.6 x 100
5188-6410
Multiple Affinity Removal Column, Hu-7 10 x 100
5188-6411
 
LC Column Specifications - Human 14
Feature Specification
   
Column Dimensions 4.6 x 50 mm (0.83 mL bed volume)
4.6 x 100 mm (1.66 mL bed volume)
10 x 100 mm (7.8 mL bed volume)
Custom sizes available
Column body material PEEK (polyetheretherketone)
End-Fitting material PEEK with 2 µm frits
Column capacity**

High-capacity serum load - 4.6 mm ID

  • 50 mm column
    Hu-7: 30 - 35 µL
  • 100 mm column
    Hu-7: 60 - 70 µL

High-capacity serum load - 10 mm ID

  • 100 mm column
    Hu-7: 250 - 300 µL
Injections/Column Standard & High-capacity > 200
Total serum/plasma processed per lifetime

High-capacity serum load - 4.6 mm ID

  • 50 mm column
    Hu-7: 7,000 µL
  • 100 mm column
    Hu-7: 14,000 µL

High-capacity serum load - 10 mm ID

  • 100 mm column
    Hu-7: 60,000 µL
Max. pressure 120 bar
Operating temperature 18 - 25oC
Column packing material Affinity resin
Immobilized ligands Affinity ligands to human (albumin, IgG, antitrypsin, IgA, transferrin and haptoglobin) or mouse high abundant proteins (albumin, IgG, and transferrin)
Flow rate range 0.25 - 3.0 mL/min
Shipping solution Buffer A with 0.02% sodium azide
Shipping temperature 2 - 8oC - (35 -46oF)
Storage temperature 2 - 8oC - (35 -46oF)
**For exact column capacity, consult your column certificate of analysis. Human and mouse sera protein concentrations can vary; injected sample sizes should be adjusted accordingly. Mouse serum capacities were determined using pooled Swiss Webster mouse serum.

 

 


 
 
©Crawford Scientific 2010