Grace Jones Genesis® Columns

Grace Jones Genesis® Columns

Genesis® columns use a new generation adsorbent based on high-purity metal-free 120Å spherical silica. Particle size offering includes 3, 4, 7, and 15μm. Genesis® columns exhibit excellent peak symmetry and exceptional pH stability from 1 to 10.

 
Click on the phase for pricing and to buy from our ecommerce site
C4 C8 C8EC
C18 Phe AQ
Petro-XP Silica CN
Amino Carbohydrate  
 

Genesis® C18 Reversed Phase

  • Excellent peak symmetry
  • Exceptional stability from pH 1 to 10
  • Reduced need for mobile-phase modifiers
  • Long column life

Genesis® C18 bonding is monomeric. A unique proprietary end-capping reagent, which is less prone to acid hydrolysis than trimethylsilane, provides freedom from residual silanols and enhanced stability under low-pH operating conditions.
Genesis® C18 columns also exhibit superior stability at alkaline pH. The permissible operating range is pH 1–10.

Genesis® AQ Reversed Phase

  • Designed for separating hydrophilic and polar compounds
  • Stable retention times in 100% aqueous mobile phases
  • Rapid equilibration
  • Unique reversed-phase selectivity

The Genesis® AQ adsorbent employs an optimum ratio of C18, short (non-TMS) chains, and polar surface groups bonded to high-purity 120Å silica to allow rapid equilibration and provide consistent, reproducible chromatography with stable retention times in 100% aqueous eluents.
Retention on Genesis® AQ is greater for polar analytes but lower for non-polar compounds compared to Genesis® C18. Uracil, which is typically an unretained peak on C18 columns, is well retained on the Genesis® AQ adsorbent. Acids and bases exhibit good peak shapes. Although Genesis® AQ excels with water-rich mobile phases, it can also be used in gradient and isocratic modes with a full spectrum of mobile phases.

Genesis® C8(EC) Reversed Phase

  • Excellent peak symmetry
  • Exceptional stability from pH 1 to 10
  • Reduced need for mobile-phase modifiers
  • Long column life

C8(EC) is double-bonded before fully endcapped using a unique proprietary end-capping reagent. It is less prone to acid hydrolysis than trimethylsilane, which provides freedom from residual silanols and enhanced stability under low-pH operating conditions. The bonding is monomeric.

Genesis® C8(EC) columns exhibit superior stability at alkaline pH.

Genesis® C8 Reversed Phase

  • Non-endcapped
  • Suitable for lower pH separations
  • Genesis® C8 bonding is monomeric. They are suitable for separations under lower pH conditions and may offer selectivity advantages for some samples.

Genesis® Phenyl

  • Unique reversed-phase chemistry
  • Improve the chromatography of polar aromatic, fatty acids, and basic pharmaceuticals
  • Genesis® Phenyl columns provide impressive peak symmetry for both acidic and basic compounds.
 
Click here to buy from our ecommerce site.
 



 
 