| you’re in > Products > Manufacturers > SGE > Agilent Technologies |
| |
Varian |
 |
| |
|
Autosampler Syringes
Varian CP8400, CP8410, CP9010, CP9050 |

|
Fixed Needle Syringes
Volume |
Needle
Length
(mm) |
Needle
Gauge |
OD
(mm) |
Tip Style |
Syringe Code |
Part no. |
| |
|
|
|
|
|
|
| 10µL |
50 |
26 |
0.47 |
Bevel |
10F-VA8400-5/0.47 |
002950 |
| 10µL |
50 |
23 |
0.63 |
Cone |
10F-C/T-5/0.63C |
002981 |
top
Removable Needle Syringes
Volume |
Needle
Length
(mm) |
Needle
Gauge |
OD
(mm) |
Tip Style |
Syringe Code |
Replacement
Needle
Part no. |
Part no. |
| |
|
|
|
|
|
|
|
| 10µL |
50 |
26 |
0.47 |
Cone |
10R-C/T-5/0.47C |
037785 |
002982 |
top
| Varian 8035, 8100, 8200 |
 |
Fixed Needle Syringes
Volume |
Needle
Length
(mm) |
Needle
Gauge |
OD
(mm) |
Tip Style |
Syringe Code |
Replacement
Plunger
Part no. |
Part no. |
| |
|
|
|
|
|
|
|
| 10µL gas tight |
53 |
25 |
0.50 |
S/Hole |
10F-VA8X-II |
031218 |
002923 |
top
Removable Needle Syringes
Volume |
Needle
Length
(mm) |
Needle
Gauge |
OD
(mm) |
Tip Style |
Syringe Code |
Replacement
Needle
Part no. |
Replacement
Plunger
Part no. |
Part no. |
| |
|
|
|
|
|
|
|
|
| 1µL |
51 |
26 |
0.47 |
Cone |
1BR-VA8X |
034720* |
|
000655 |
| 10µL gas tight |
53 |
25 |
0.50 |
S/Hole |
10R-VA8X-II |
037777 |
031218 |
002924 |
| 100µL |
53 |
25 |
0.50 |
S/Hole |
100R-VA8X |
038745 |
031824 |
005921 |
Please note that p/n 000655 is not suitable for the 8200 autosampler.
*Denotes spare Needle and Plunger kit.
top
Liners
Varian 1177 Liners
Varian 1075/1077 Liners
Description |
OD (mm) |
ID (mm) |
Length (mm) |
Pack Size |
Part no. |
| |
|
|
|
|
|

Split,
FAST FocusLiner |
6.3 |
2.3 |
72 |
5 |
092113 |

Split
with Quartz Wool |
6.3 |
4 |
72 |
5 |
092021 |

Split
FocusLiner with Top-end Restriction |
6.3 |
4 |
72 |
5 |
092028 |

Splitless
FocusLiner with Top-end Restriction |
6.3 |
4 |
74 |
5 |
092026 |

Split,
Tapered FocusLiner |
6.3 |
4 |
72 |
5 |
092025 |

Splitless,
Slots at Both Ends |
6.3 |
2 |
74 |
5 |
092024 |

Split
FocusLiner |
6.3 |
4 |
72 |
5 |
092022 |
.gif)
Splitless,
Slots at Both Ends |
6.3 |
2 |
74 |
25 |
092228 |
top
Varian 1078/1079 Liners
Description |
OD (mm) |
ID (mm) |
Length (mm) |
Pack Size |
Part no. |
| |
|
|
|
|
|

Sintered
Glass, Large Volume Injection (LVI) Liner |
5 |
1.8/3.4 |
54 |
5 |
092245 |

Straight-through
Liner |
5 |
0.5 |
54 |
5 |
092031 |

SPME
liner |
5 |
0.75 |
54 |
5 |
092117 |

Splitless
with Single Taper |
5 |
2 |
54 |
5 |
092039 |

Split /
Splitless with single taper |
5 |
3.4 |
54 |
5 |
092038 |

Split /
Splitless FocusLiner |
5 |
3.4 |
54 |
5 |
092037 |

Split /
Splitless Tapered FocusLiner |
5 |
3.4 |
54 |
5 |
092036 |
top
Varian 1093/1094 Liners
Description |
OD (mm) |
ID (mm) |
Length (mm) |
Pack Size |
Part no. |
| |
|
|
|
|
|

SPI
Liner, (Restriction = 0.25mm) |
4.6 |
0.5 |
54 |
5 |
092027 |

SPI
Liner, (Restriction = 0.5mm) for 0.53mm ID On-column |
4.6 |
0.8 |
54 |
5 |
092034 |

SPI
Liner, (Restriction = 0.25mm) |
4.6 |
0.8 |
54 |
5 |
092030 |
top
Varian Packed Column Liners
Description |
OD (mm) |
ID (mm) |
Length (mm) |
Pack Size |
Part no. |
| |
|
|
|
|
|

Packed
Column Liner for Varian Flash Injectors |
6.3 |
3 |
72 |
1 |
092232 |
.gif)
Packed
Column Liner for Varian Flash Injectors |
6.3 |
3 |
72 |
5 |
092233 |
top
Liner O-rings
Description |
Pack Size |
Part no. |
| |
|
|
Viton O-Ring - Can be used at temperatures up to 300°C
For 1177
injector |
10 |
0726532 |
| Graphite Sealing Ring - For 1075 & 1077 Injectors |
10 |
072601 |
| Graphite Sealing Ring - For 1078 & 1079 Injectors |
10 |
0726217 |
top
Septa
Model |
Diameter (mm) |
Septum Type |
Pack Size |
Part no. |
| |
|
|
|
|
| 1177 Injector |
9 |
CS |
50 |
041824 |
| 1177 Injector |
9 |
TCS |
50 |
041844 |
| 1177 Injector |
9 |
TCS Pre-drilled |
50 |
041854 |
| 1177 Injector |
9 |
Auto-Sep T™ |
25 |
041879 |
| 1040, 1041, 1060 & 1061 Injectors |
9.5 |
CS |
50 |
0418240 |
| 1040, 1041, 1060 & 1061 Injectors |
9.5 |
TCS |
50 |
0418440 |
| 1040, 1041, 1060 & 1061 Injectors |
9.5 |
TCS Pre-drilled |
50 |
0418540 |
| 1040, 1041, 1060 & 1061 Injectors |
9.5 |
Auto-Sep™ |
25 |
041871 |
| 1040, 1041, 1060 & 1061 Injectors |
9.5 |
Auto-Sep T™ |
100 |
041881 |
| 1075, 1077, 1078, 1079 injectors & 1093, 1094 SPI Injectors |
11 |
CS |
50 |
041826 |
| 1075, 1077, 1078, 1079 injectors & 1093, 1094 SPI Injectors |
11 |
TCS |
50 |
041846 |
| 1075, 1077, 1078, 1079 injectors & 1093, 1094 SPI Injectors |
11 |
TCS Pre-drilled |
50 |
041856 |
| 1075, 1077, 1078, 1079 injectors & 1093, 1094 SPI Injectors |
11 |
Auto-Sep™ |
25 |
041872 |
| 1075, 1077, 1078, 1079 injectors & 1093, 1094 SPI Injectors |
11 |
Auto-Sep T™ |
25 |
041882 |
| 1075, 1077, 1078, 1079 injectors & 1093, 1094 SPI Injectors |
11 |
Auto-Sep T™ |
100 |
041883 |
top
Ferrules
All ferrules are supplied in packets of 10.
Detector / Injectors
(Not for GC/MS Interface
Connections)
Column Size |
Material |
Part no. |
| |
|
|
| 0.10-0.25mm ID columns |
15% Graphite/ 85% Vespel® |
072663 |
| 0.32mm ID columns |
100% Graphite |
072627 |
| 0.32mm ID columns |
15% Graphite/ 85% Vespel® |
072654 |
| 0.32mm ID columns |
100% Graphite |
072627 |
| 0.45-0.53mm ID columns |
15% Graphite/ 85% Vespel® |
072655 |
| 0.45-0.53mm ID columns |
100% Graphite |
072626 |
| 1/8" OD packed columns |
15% Graphite/ 85% Vespel® |
072669 |
| 1/8" OD packed columns |
100% Graphite |
072622 |
| 1/4" OD packed columns |
15% Graphite/ 85% Vespel® |
072667 |
| 1/4" OD packed columns |
100% Graphite |
072621 |
top
GC/MS Interface Connections
Column Size |
Description |
Part no. |
| |
|
|
| 0.10-0.25mm ID columns |
SilTite Metal - Initial Installation (10 ferrules, 2 nuts) |
073300 |
| 0.10-0.25mm ID columns |
SilTite Ferrules |
073220 |
| 0.10-0.25mm ID columns |
15% Graphite/ 85% Vespel® Ferrules |
072663 |
| 0.32mm ID columns |
SilTite Metal - Initial Installation (10 ferrules, 2 nuts) |
073301 |
| 0.32mm ID columns |
SilTite Ferrules |
073221 |
| 0.32mm ID columns |
15% Graphite/ 85% Vespel® Ferrules |
072654 |
| 0.45-0.53mm ID columns |
SilTite Metal - Initial Installation (10 ferrules, 2 nuts) |
073302 |
| 0.45-0.53mm ID columns |
SilTite Ferrules |
073222 |
| 0.45-0.53mm ID columns |
15% Graphite/ 85% Vespel® Ferrules |
072655 |
|
SilTite Metal Nuts (packet of 5) |
073231 |
top
Electron
Multipliers
Instrument |
Analyzer Type |
Technique |
Part no. |
| |
|
|
|
| Saturn 2000, 2100, 2200 |
Ion Trap |
GC-MS |
14147 |
| Saturn (pre-2000) |
Ion Trap |
GC-MS |
14138 |
top
|
|