YMC-BioPro IEX Columns

  • newly developed porous hydrophilic polymer with low nonspecific adsorption
  • excellent binding capacity and recovery of biomolecules
  • very high resolution
YMC-BioPro Series
YMC-BioPro QA-F
YMC-BioPro SP-F
Matrix
hydrophilic polymer bead
hydrophilic polymer bead
Pore size(nm)
nonporous
nonporous
Particle size(μm)
5
5
Charged group
-CH2N+(CH3)3
-CH2CH2CH2SO3
Counter ion
Cl-
Na+
Ion-exchange capacity
0.075-0.110 meq/ml-resin 0.230-0.290 meq/ml-resin
Dynamic binding capacity
12-20 mg-BSA/ml-resin 10-18 mg-human IgG/ml-resin
Available pH range
2.0 - 12.0 2.0 - 12.0
 
 
High efficiency with a lower column pressure
 
Column Dimension Part Number
YMC-BioPro SP-F 30x4.6 mm ID
SF00S050346WP
YMC-BioPro QA-F 30x4.6 mm ID
QF00S050346WP
YMC-BioPro SP-F 50x4.6 mm ID
SF00S050546WP
YMC-BioPro QA-F 50x4.6 mm ID
QF00S050546WP
YMC-BioPro SP-F 100x4.6 mm ID
SF00S051046WP
YMC-BioPro QA-F 100x4.6 mm ID
QF00S051046WP
 
 
Comparison of column efficiency on non-porous polymer based columns*
 
YMC-BioPro IEX Columns Chromatograms
 
Compared with the competitors’ columns, YMC-BioPro QA-F and SP-F show high theoretical plate counts, excellent peak shapes, and low pressure. Therefore, YMC-BioPro QA-F and SP-F is suitable for high-throughput analysis.
Eluent: 20 mM Tris-HCl (pH 8.1) (for anion exchange columns)
20 mM KH2PO4-K2HPO4 (pH 6.8) (for cation exchange columns)
Flow rate: 0.12 ml/min
Temperature: 25 °C
Detection: UV at 220 nm
Injection: 20 μl
Sample: Formamide (2 μl/ml)
 
 
High throughput analysis of proteins*
 

YMC-BioPro IEX Columns Chromatograms
 

YMC-BioPro SP-F can separate the proteins sharply without the peak-tailing observed in the chromatography of competitor’s SP-NPR. Furthermore, despite having a larger particle size, the theoretical plate number of YMCBioPro SP-F is higher.
 
Eluent:

A) 20 mM KH2PO4-K2HPO4 (pH 6.8)

B) 20 mM KH2PO4-K2HPO4 (pH 6.8) containing 0.5M NaCl

Gradient: YMC-Bio SP-F 0-100% B (0-4 min)
TSKgel SP-NPR 0-100% B (0-4.67 min)
Flow rate: 1.5 ml/min
Temperature: 25 °C
Detection: UV at 220 nm
Injection: 20 μl
Sample: 1. Ribonuclease A (0.1 mg/ml)
2. Cytochrome c (0.1 mg/ml)
 
 
Long column for high resolution analysis*
YMC-BioPro IEX Columns Chromatograms
The theoretical plate count for the 100 mm column is about 5 times higher than 30 mm column, making it very useful for high-resolution analyses.
Eluent: 20 mM Tris-HCl (pH 8.1)
Flow rate: 0.12 ml/min
Temperature: 25 °C
Detection: UV at 220 nm
Injection: 20 μl
 
 
Application - Nucleotides -*
 
YMC-BioPro IEX Columns Chromatograms
 
Elution of DNA fragments is optimised on 100 mm columns. The sensitivity is improved by reducing the gradient to half. In addition, the analysis time can be shortened by increasing the buffer concentration, while maintaining excellent resolution.
Column: YMC-BioPro QA-F, 5 μm, 100 x 4.6 mm i.d.
Eluent: Eluent: A) 20 mM Tris HCl (pH 8.1) containing 0.5M NaCl
B) 20 mM Tris HCl (pH 8.1) containing 1.0M NaCl
Flow rate: 0.5 ml/min
Temperature: 25 °C
Detection: UV at 260 nm
Injection: 20 μl
Sample: 1 Kb DNA Ladder (0.25 mg/ml)
 
*By courtesy of YMC Co., Ltd.
 
  