Agilent AdvanceBio Oligonucleotide Columns
AdvanceBio Oligonucleotide HPLC Columns from Agilent
To successfully separate trityl-off, deprotected oligonucleotides, you need columns that have high resolving power and are robust enough to withstand challenging conditions.
If your columns don’t provide enough resolution, you can’t be sure your results are accurate. If your columns are not robust, you will have to replace them frequently, which will disrupt your workflow and increase your costs. Agilent AdvanceBio oligonucleotide columns feature high efficiency, 2.7 µm superficially porous Poroshell particles. Using technology exclusive to Agilent, we chemically modify the particles to make them exceedingly resistant to high pH mobile phases. We also bond them with an end-capped C18 phase that delivers excellent selectivity for oligonucleotides. What’s more, we test every batch of AdvanceBio oligonucleotide media with a resolution standard to ensure consistent performance.
The family of AdvanceBio products are designed to deliver consistent, exceptional performance for the complete characterization of proteins, antibodies, conjugates, new biological entities and biopharmaceuticals.
AdvanceBio Oligonucleotide columns from Agilent are high-quality, high-resolution ion-pair reversed-phase (IP-RP) columns, which supports analytical characterisation and purification with seamless method scalability. These columns are designed to effectively separate trityl-off, deprotected oligonucleotides, with high resolving power and durability to withstand high pH and temperatures for superior separation and denaturing conditions for enhancing resolution and oligonucleotide separation.
The columns utilise high-efficiency, 2.7 and 4 μm superficially porous Poroshell particles. Exclusive Agilent technology allows for the chemical modification of these particles, increasing their resistance to high pH mobile phases. The particles are also bonded with an end-capped C18 phase, ensuring excellent selectivity for oligonucleotides. Each batch of AdvanceBio Oligonucleotide media is rigorously tested against a resolution standard to guarantee consistent performance.
- Designed for ion-pair reversed-phase separation of the trityl-off, deprotected oligos using either TEAA or TEA-HFIP
- Features the HPH-C18 robust column chemistry technology which is stable at elevated pH and temperatures
- Streamlines scale up from analytical characterization to preparative purification
- Every batch of AdvanceBio Oligonucleotide media is tested with the Agilent Oligonucleotide Resolution standard
AdvanceBio Oligonucleotide | |
Bonded Phase | C18 |
Particle Type | Superficially Porous |
Endcapped | Double |
Particle Size | 2.7 µm, 4 µm |
Pore Size | 120 Å |
Temp Limits | 65°C |
pH range | 3 - 11 |