Agilent CP-Al2O3 PLOT GC Columns

Agilent J&W Aluminum oxide PLOT columns offer high selectivity for separating ppm levels of C1 – C5 hydrocarbons in process streams. These columns analyse more compounds in a single run than packed columns, while still delivering higher resolution and faster analysis times. Choice of two selectivities covers a broad range of applications

CP Al2O3/KCl has an apolar surface to separate ppm levels of C1 – C5 hydrocarbons in a main stream of C1 – C5 hydrocarbons
CP Al2O3/Na2SO4 has a polar surface to separate ppm levels of C1 – C5 hydrocarbons in a main stream of C1 – C5 hydrocarbons

Part Number Short Description Film Thickness Phase ID Length Type Material Price Qty
CP7511 CP-Al2O3/KCl, 10m x 0.32mm x 5um 5 um CP-Al2O3/KCl 0.32 mm 10 m 7 inch Fused Silica
£385.00
CP7576 CP-Al2O3/KCl, 25m x 0.25mm x 4um 4 um CP-Al2O3/KCl 0.25 mm 25 m 7 inch Fused Silica
£636.00
CP7519 CP-Al2O3/KCl, 25m x 0.32mm x 5um 5 um CP-Al2O3/KCl 0.32 mm 25 m 7 inch Fused Silica
£684.00
CP7517 CP-Al2O3/KCl, 25m x 0.53mm x 10um 10 um CP-Al2O3/KCl 0.53 mm 25 m 7 inch Fused Silica
£636.00
CP7517PT CP-Al2O3/KCl, 25m x 0.53mm x 10um, with 2PT 10 um CP-Al2O3/KCl 0.53 mm 25 m 7 inch Fused Silica
£732.00
CP7577 CP-Al2O3/KCl, 50m x 0.25mm x 4um 4 um CP-Al2O3/KCl 0.25 mm 50 m 7 inch Fused Silica
£1,089.00
CP7515 CP-Al2O3/KCl, 50m x 0.32mm x 5um 5 um CP-Al2O3/KCl 0.32 mm 50 m 7 inch Fused Silica
£1,184.00
CP7515I5 CP-Al2O3/KCl, 50m x 0.32mm x 5um, 5in cage 5 um CP-Al2O3/KCl 0.32 mm 50 m 5 inch Fused Silica
£1,328.00
CP7515PT CP-Al2O3/KCl, 50m x 0.32mm x 5um, with 2PT 5 um CP-Al2O3/KCl 0.32 mm 50 m 7 inch Fused Silica
£1,474.00
CP7518 CP-Al2O3/KCl, 50m x 0.53mm x 10um 10 um CP-Al2O3/KCl 0.53 mm 50 m 7 inch Fused Silica
£1,217.00
CP7518PT CP-Al2O3/KCl, 50m x 0.53mm x 10um, with 2PT 10 um CP-Al2O3/KCl 0.53 mm 50 m 7 inch Fused Silica
£1,333.00
CP6918 CP-Al2O3/KCl, UltiMetal, 50m x 0.53mm x 10um 10 um CP-Al2O3/KCl 0.53 mm 50 m 7 inch UltiMetal
£1,460.00
CP7586 CP-Al2O3/Na2SO4, 25m x 0.25mm x 4um 4 um CP-Al2O3/Na2SO4 0.25 mm 25 m 7 inch Fused Silica
£636.00
CP7567 CP-Al2O3/Na2SO4, 25m x 0.53mm x 10um 10 um CP-Al2O3/Na2SO4 0.53 mm 25 m 7 inch Fused Silica
£636.00
CP7587 CP-Al2O3/Na2SO4, 50m x 0.25mm x 4um 4 um CP-Al2O3/Na2SO4 0.25 mm 50 m 7 inch Fused Silica
£1,089.00
CP7565 CP-Al2O3/Na2SO4, 50m x 0.32mm x 5um 5 um CP-Al2O3/Na2SO4 0.32 mm 50 m 7 inch Fused Silica
£1,184.00
CP7565I5 CP-Al2O3/Na2SO4, 50m x 0.32mm x 5um, 5in cage 5 um CP-Al2O3/Na2SO4 0.32 mm 50 m 5 inch Fused Silica
£1,267.00
CP7565PT CP-Al2O3/Na2SO4, 50m x 0.32mm x 5um, with 2PT 5 um CP-Al2O3/Na2SO4 0.32 mm 50 m 7 inch Fused Silica
£1,474.00
CP7568 CP-Al2O3/Na2SO4, 50m x 0.53mm x 10um 10 um CP-Al2O3/Na2SO4 0.53 mm 50 m 7 inch Fused Silica
£1,217.00
CP7568PT CP-Al2O3/Na2SO4, 50m x 0.53mm x 10um, with 2PT 10 um CP-Al2O3/Na2SO4 0.53 mm 50 m 7 inch Fused Silica
£1,333.00
CP6968 CP-Al2O3/Na2SO4, UltiMetal, 50m x 0.53mm x 10um 10 um CP-Al2O3/Na2SO4 0.53 mm 50 m 7 inch UltiMetal
£1,460.00

CP-Al2O3/KCl GC Columns

Agilent J&W CP-Al2O3/KCl is an aluminum oxide PLOT column that offers high selectivity for separating ppm levels of C1 – C5 hydrocarbons in a main stream of C1 – C5 hydrocarbons. The KCl deactivation salt results in relatively apolar Al2O3 surface. These columns analyse more compounds in a single run than packed columns, while still delivering higher resolution and faster analysis times. When compared to liquid stationary phases, CP-Al2O3 provides increased selectivity and allows all C1 – C5 hydrocarbon isomers to be separated. CP-Al2O3 operates without the need for sub-ambient cooling.

  • The KCl deactivation salt results in a relatively apolar Al2O3 surface
  • High capacity thick films
  • No need for sub-ambient cooling simplifies operation
  • Available in Fused Silica and UltiMetal

Similar Phases: Al2O3/KCl, Rt-Alumina PLOT, Alumina PLOT, RT-Alumina BOND/KCl, Alumina chloride PLOT, AB-PLOT Al2O3 KCl


CP-Al2O3/Na2SO4 GC Columns

Agilent J&W CP-Al2O3/Na2SO4 is an aluminum oxide PLOT column that offers high selectivity for separating ppm levels of C1 – C5 hydrocarbons in a main stream of C1 – C5 hydrocarbons. The Na2SO4 deactivation salt provides a polar Al2O3 surface, so that unsaturated compounds such as ethylene and acetylene are retained longer. These columns analyse more compounds in a single run than packed columns, while still delivering higher resolution and faster analysis times. When compared to liquid stationary phases, CP-Al2O3 provides increased selectivity and allows all C1 – C5 hydrocarbon isomers to be separated. CP-Al2O3 operates without the need for sub-ambient cooling.

  • The Na2SO4 deactivation provides a polar surface. Unsaturated compounds such as ethylene and acetylene (ethyne) are retained longer
  • High capacity thick films
  • No need for sub-ambient cooling simplifies operation
  • Available in Fused Silica and UltiMetal

Similar Phases: Al2O3/Na2SO4, Rt-Alumina PLOT, Alumina PLOT, Rt-Alumina BOND/Na2SO4, MXT-AluminaBOND/Na2SO4, Alumina sulfate PLOT


UltiMetal columns are engineered to combine the robustness of stainless steel with advanced surface deactivation for excellent peak shape. 


A 7 inch cage is the most common GC column format, compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems, and all non-Agilent GC systems with a similarly sized oven. The 5 inch cage format is designed for smaller GC ovens e.g. for the Agilent GC 6850.

CP-Al2O3/KCl Temperature Specifications

ID 0.25 – 0.53 mm
Length 10 – 50 m
Film 4 – 10 µm
Temperature Limits -100 – 200/200°C 

 

CP-Al2O3/Na2SO4 Temperature Specifications

ID 0.25 – 0.53 mm
Length 10 – 50 m
Film 4 – 10 µm
Temperature Limits -100 – 200/200°C 
Agilent GC Column Brochure (11.67 MB)

Full range of Agilent Technologies GC columns and applications

Voids in PLOT Columns (65.06 kB)
What causes the spots on the PLOT columns?
Copyright © 2023 Element Materials Technology