Agilent J&W CP-Sil 5 CB is a high efficiency column containing a 100% dimethylpolysiloxane phase. Separation is almost entirely based on boiling points, making this column suitable for a wide range of applications. A number of configurations are available to allow for different uses, including GC/MS and specific applications.
CP-Sil 5 CB – low polarity 100% dimethylpolysiloxane column adopted for a wide range of applications
CP-Sil 5 CB-ms – optimized for GC/MS applications
CP-Sil 5 CB for Formaldehyde – optimized for the analysis of formaldehyde, water, and methanol in petroleum and petrochemical applications
CP-Sil 5 CB for Sulfur – optimized for the analysis of volatile sulfur compounds in petroleum and energy applications
CP-Sil 5/C18 CB for PCB – specially processed for extended temperature limit of 400°C
Agilent J&W CP-Sil 5 CB is a high efficiency column containing a 100% dimethylpolysiloxane phase. Separation is almost entirely based on boiling points, making this column suitable for a wide range of applications with a broad temperature range. Due to intensive cross-linking, CP-Sil 5 CB is highly inert and withstands large solvent injections, guaranteeing reproducibility and ensuring maximum column lifetime. For the highest operating temperatures, use our UltiMetal columns.
100% Dimethylpolysiloxane
Non-polar
General purpose phase
Bonded, cross-linked and solvent rinsable
Separation almost entirely based on boiling points, making this column suitable for a wide range of applications with a broad temperature range
Available in Fused Silica or UltiMetal to maximize choice
Agilent J&W CP-Sil 5 CB-ms is a high efficiency column containing a 100% dimethylpolysiloxane phase. GC/MS columns are specifically designed to chromatograph a broad range of trace-level samples, and offer low bleed and high inertness.
100% Dimethylpolysiloxane
Non-polar
Optimized for GC/MS applications
CP-Sil 5 CB for Formaldehyde GC Columns
Agilent J&W CP-Sil 5 CB for Formaldehyde is optimized for the analysis of formaldehyde, water and methanol, and can deliver trace analysis of sulfur compounds and partial permanent gases (especially in switching systems). The nonpolar phase provides accurate separations based on volatility.
Optimized for analysis of formaldehyde, water and methanol
Trace analysis of sulfur compounds possible
Partial permanent gas analysis possible (especially in switching systems)
Non-polar phase provides accurate separations based on volatility
High inertness, elutes sulfur components without absorption for high quality data and low detection limits
Highest efficiency for this apolar column with the thickest film
CP-Sil 5 CB for Sulfur GC Columns
Agilent J&W CP-Sil 5 CB for Sulfur is optimized for the analysis of volatile sulfur compounds, with trace analysis of sulfur compounds to C7 mercaptan for high productivity. The column is a nonpolar phase that gives accurate separations based on volatility. Its high inertness elutes sulfur dioxide for high quality data and low detection limits.
Optimized for analysis of Volatile Suflur Compounds
Trace analysis of volatile sulfur compounds to C7 mercaptan for higher productivity
Non-polar phase providing accurate results based on volatility
High inertness, elutes SO2 for high quality data and low detection limits
CP-Sil 5/C18 CB for PCB GC Columns
Agilent J&W CP-Sil 5/C18 CB for PCB has a lower polarity than 100% polydimethylsiloxane due to its C18 substitutions. With an absence of cyano groups, the column provides high signal-to-noise ratios for ECD detectors. The 100 m column separates critical isomer pairs: 28/31, 56/60, 149/118, 105/153/132 and 170/190.
Engineered for high resolution PCB analysis
Lower polarity than 100% polydimethylpolysiloxane due to its C18 substitution
Provides high signal-to-noise ratios for ECD detectors
Optimized column length for separation of critical isomer pairs: 28/31, 56/60, 149/118, 105/153/132 and 170/190