DB-35
J&W DB-35 GC Columns from Agilent
Agilent J&W DB-35 is a (35%-phenyl)-methylpolysiloxane, mid-polarity column with low bleed.
- DB-35 - mid-polarity, low bleed column excellent for environmental analyses
- DB-35ms - offers excellent inertness for active compounds while providing very low-bleed characteristics
- DB-35ms Ultra Inert - improved inertness and exceptionally low bleed, with great peak shapes for challenging, active analytes such as pesticides and drugs of abuse
DB-35 GC Columns
Agilent J&W DB-35 columns are ideal for conformational analysis. The DB-35 is a (35%-phenyl)-methylpolysiloxane, mid-polarity column with low bleed. Being bonded and cross-linked, it is inert to active solutes. DB-35 is a close equivalent to USP phase G42.
- (35%-Phenyl)-methylpolysiloxane
- Mid polarity—slightly more polar than HP-35
- Low bleed
- Inert to active solutes
- Ideal for confirmational analyses
- Bonded and cross-linked and solvent rinsable
- Equivalent to USP Phase G42
Similar Phases: Rtx-35, Rtx-35ms, Rxi-35Sil MS, SPB-35, AT-35, Sup-Herb, MDN-35, BPX-34, ZB-35, ZB-35 ht
DB-35ms GC Columns
Agilent J&W DB-35 columns are ideal for conformational analysis. The DB-35 is a (35%-phenyl)-methylpolysiloxane, mid-polarity column with low bleed. Being bonded and cross-linked, it is inert to active solutes. DB-35 is a close equivalent to USP phase G42.
- Virtually equivalent to (35%-Phenyl)-methylpolysiloxane
- Mid polarity with very low bleed characteristics, ideal for GC/MS
- Extended temperature limit of 340/360 °C
- Excellent inertness for active compounds
- Ideal for confirmational analyses
- Close equivalent to USP Phase G42
- Bonded, cross-linked and solvent rinsable
- Replaces HP-35ms
Similar Phases: Rtx-35, Rtx-35ms, Rxi-35Sil MS, SPB-35, AT-35, Sup-Herb, MDN-35, BPX-34, ZB-35, ZB-35 ht
DB-35ms Ultra Inert GC Columns
Agilent J&W DB-35ms Ultra Inert is a mid-polar column, for applications where different selectivity is needed for enhanced separations, including pesticide analysis and drugs of abuse testing. DB-35ms Ultra Inert quantifies components at a lower level, with broader linearity and optimized separation, ultimately increasing productivity..
- Individually tested with the Ultra Inert DB-35ms test probe mixture
- Consistent column inertness performance
- Exceptionally low column bleed
- Great peak shapes for challenging active analytes and excellent signal-to-noise ratios
- Minimum compound adsorption or degradation
- Support of 0.18 mm id column configuration for higher sample throughput
Similar Phases: Rtx-35, Rtx-35ms, Rxi-35Sil MS, SPB-35, AT-35, Sup-Herb, MDN-35, BPX-34, ZB-35, ZB-35 ht
DB-35 Temperature Specifications
ID (mm) | 0.25 – 0.32 mm | 0.53 mm |
Length (m) | 30 - 60 m | 15 - 30 m |
Film (µm) | 0.25 - 0.50 µm | 0.50 - 1.00 µm |
Temperature Limits (°C) | 40 - 300/320 °C | 40 - 280/300 °C |
DB-35ms Ultra Inert Temperature Specifications
ID (mm) | 0.18 – 0.32 mm |
Length (m) | 15 – 30 m |
Film (µm) | 0.18 – 0.25 µm |
Temperature Limits (°C) | 50 – 340/360 °C |