Ohio Valley OV-PLOT GC Columns
Ohio Valley OV-PLOT column phases include OV-PLOT Q, OV-PLOT U and OV-PLOT GasPro:
OV-PLOT Q phase consists of a porous divinylbenzene polymer
OV-PLOT U phase consists of a porous divinylbenzene, ethylene glycol dimethacrylate co-polymer
OV-PLOT GasPro phase consists of a proprietary porous silica layer
OV-PLOT Q and OV-PLOT U columns are used for the analysis of natural gas, refinery gases, chemical weapon gas, CFCs, sulfurs, and amines.
OV-PLOT GasPro columns are used for the analysis of sulfur analysis, CFCs, light hydrocarbons, and solvents.
OV-PLOT Q
- Porous divinylbenzene polymer
- Excellent immobilised, rinseable with volatile solvents
- Used for the analysis of natural gas, refinery gases, chemical weapon gas, CFCs, sulfurs, and amines
- Good separations of volatile sulfurs, CO2, methane, oxygenate solvent vapors from light hydrocarbon C1 – C4 stream
- Separates ethane, ethylene, and acetylene
Applications: air, carbon monoxide, methane, carbon dioxide, hydrocarbon gases, oxygenates, alcohols, N2OI, refinery gas I, fatty acids (free), natural gas, solvents, gases (air, carbon monoxide, methane, carbon dioxide), nitrogen, oxygen, argon, sulfur gas analysis of light hydrocarbon streams
Similar Phases: AT-Q, CP-PoraPlot Q, GS-Q, HP-PLOT Q, Rt-Q, Rt-Q-BOND, Rtx-QS, Supel-Q-PLOT
OV-PLOT U
- Porous divinylbenzene, ethylene glycol dimethacrylate co-polymer
- Used for the analysis of natural gas, refinery gases, chemical weapon gas, CFCs, sulfurs, and amines
- Good separations of volatile sulfurs, amines, acids, CO2, oxygenate solvent vapors from light hydrocarbon C1 – C4 stream
Applications: amines in water, primary amines, CO2 in air, moisture, hydrocarbon gases, solvents, N2/CO, sulfurs
Similar Phases: CP-PoraPLOT U, CP-PoraBOND U, HP-PLOT U, Rt-U-BOND
OV-PLOT GasPro
- Proprietary porous silica layer
- Immobilised, rinseable with methanol, acetone, & pentane
- High plate numbers
- 0.32mm ID columns only
- Used for the analysis of sulfurs, CFCs, light hydrocarbons, and solvent
- Good separations of volatile sulfurs, CO2, solvents, and light hydrocarbons C1 – C5
- Separates CO and CO2 on a single column
Applications: C1 and C2 halocarbons (freon), halothane, residue solvents, extended hydrocarbon analysis, inorganic gases, sulfur compounds in propylene (1 ppm), halocarbons, mercaptans, sulfur gas analysis in light hydrocarbon streams, Method ASTM D 2505, Method ASTM D 5303.
Similar Phases: CP-Silica PLOT, GS-GasPro
OV-PLOT Q Temperature Specifications
ID | 0.25 – 0.53 mm |
Length | 10 – 50 m |
Film | 5 – 30 µm |
Temperature Limits | -80 – 280°C |
OV-PLOT U Temperature Specifications
ID | 0.25 – 0.53 mm |
Length | 15 – 30 m |
Film | 5 – 20 µm |
Temperature Limits | -80 – 190/200°C |
OV-PLOT GasPro Temperature Specifications
ID | 0.32 mm |
Length | 5 – 60 m |
Film | 5 µm |
Temperature Limits | -80 – 260/300°C |