HALO® C30 HPLC Columns from Advanced Materials Technology

HALO® C30 Analytical HPLC Columns from AMT

HALO 160 Ã… C30 is a high-speed, high-performance liquid chromatography column based on the wider-pore 160 Ã… Fused-Core® particle design to provide adequate spacing for the long-chain C30 ligands. The Fused-Core® particle provides a thin porous shell of high-purity silica surrounding a solid silica core. This particle design exhibits very high column efficiency due to the shallow diffusion paths in the 0.5 µm thick porous shell and the small overall particle size of 2.7 µm. The endcapped triacontrylsilane stationary phase of HALO 160 Ã… C30 provides a stable, reversed-phase packing that can be used for hydrophobic, long-chain, structural isomers, such as vitamins and lipids.

HALO 160 Å C30 is a high-speed, high-performance liquid chromatography column based on the wider-pore 160 Å Fused-Core® particle design to provide adequate spacing for the long-chain C30 ligands. The Fused-Core® particle provides a thin porous shell of high-purity silica surrounding a solid silica core. This particle design exhibits very high column efficiency due to the shallow diffusion paths in the 0.5 µm thick porous shell and the small overall particle size of 2.7 µm. The endcapped triacontrylsilane stationary phase of HALO 160 Å C30 provides a stable, reversed-phase packing that can be used for hydrophobic, long-chain, structural isomers, such as vitamins and lipids.

HALO® C30 HPLC columns from Advanced Materials Technology are designed to deliver fast reversed phase separations of hydrophobic, long-chain structural isomers such as vitamins and lipids. High shape selectivity enhances separations compared to standard C18 phases. The HALO® C30 phase with 160 Å is built on 2.7 µm Fused-Core® particle technology for fast, high efficiency separations with low backpressures.

Part Number Short Description Phase Type Phase USP Particle Size ID Length Pore Size Type Price Qty
91216-602 HALO 160A C30, 2.7um, 0.3 x 100mm C30 HALO C30 L62 2.7 um 0.3 mm 100 mm 160 A Column
£906.52
91216-702 HALO 160A C30, 2.7um, 0.3 x 150mm C30 HALO C30 L62 2.7 um 0.3 mm 150 mm 160 A Column
£906.52
91216-402 HALO 160A C30, 2.7um, 0.3 x 50mm C30 HALO C30 L62 2.7 um 0.3 mm 50 mm 160 A Column
£820.89
91215-602 HALO 160A C30, 2.7um, 0.5 x 100mm C30 HALO C30 L62 2.7 um 0.5 mm 100 mm 160 A Column
£906.52
91215-702 HALO 160A C30, 2.7um, 0.5 x 150mm C30 HALO C30 L62 2.7 um 0.5 mm 150 mm 160 A Column
£906.52
91215-402 HALO 160A C30, 2.7um, 0.5 x 50mm C30 HALO C30 L62 2.7 um 0.5 mm 50 mm 160 A Column
£820.89
92111-602 HALO 160A C30, 2.7um, 1 x 100mm C30 HALO C30 L62 2.7 um 1.0 mm 100 mm 160 A Column
£726.92
92111-702 HALO 160A C30, 2.7um, 1 x 150mm C30 HALO C30 L62 2.7 um 1.0 mm 150 mm 160 A Column
£790.98
92111-402 HALO 160A C30, 2.7um, 1 x 50mm C30 HALO C30 L62 2.7 um 1.0 mm 50 mm 160 A Column
£654.11
92112-630 HALO 160A C30, 2.7um, 2.1 x 100mm C30 HALO C30 L62 2.7 um 2.1 mm 100 mm 160 A Column
£697.03
92112-730 HALO 160A C30, 2.7um, 2.1 x 150mm C30 HALO C30 L62 2.7 um 2.1 mm 150 mm 160 A Column
£761.09
92112-230 HALO 160A C30, 2.7um, 2.1 x 20mm C30 HALO C30 L62 2.7 um 2.1 mm 20 mm 160 A Column
£547.33
92112-930 HALO 160A C30, 2.7um, 2.1 x 250mm C30 HALO C30 L62 2.7 um 2.1 mm 250 mm 160 A Column
£974.85
92112-330 HALO 160A C30, 2.7um, 2.1 x 30mm C30 HALO C30 L62 2.7 um 2.1 mm 30 mm 160 A Column
£547.33
92112-430 HALO 160A C30, 2.7um, 2.1 x 50mm C30 HALO C30 L62 2.7 um 2.1 mm 50 mm 160 A Column
£619.94
92112-130 HALO 160A C30, 2.7um, 2.1 x 5mm, Guard Column 3pk C30 HALO C30 L62 2.7 um 2.1 mm 5 mm 160 A Guard
£525.97
92112-530 HALO 160A C30, 2.7um, 2.1 x 75mm C30 HALO C30 L62 2.7 um 2.1 mm 75 mm 160 A Column
£645.57
92113-630 HALO 160A C30, 2.7um, 3 x 100mm C30 HALO C30 L62 2.7 um 3.0 mm 100 mm 160 A Column
£697.03
92113-730 HALO 160A C30, 2.7um, 3 x 150mm C30 HALO C30 L62 2.7 um 3.0 mm 150 mm 160 A Column
£761.09
92113-230 HALO 160A C30, 2.7um, 3 x 20mm C30 HALO C30 L62 2.7 um 3.0 mm 20 mm 160 A Column
£547.33
92113-930 HALO 160A C30, 2.7um, 3 x 250mm C30 HALO C30 L62 2.7 um 3.0 mm 250 mm 160 A Column
£974.85
92113-330 HALO 160A C30, 2.7um, 3 x 30mm C30 HALO C30 L62 2.7 um 3.0 mm 30 mm 160 A Column
£547.33
92113-430 HALO 160A C30, 2.7um, 3 x 50mm C30 HALO C30 L62 2.7 um 3.0 mm 50 mm 160 A Column
£619.94
92113-130 HALO 160A C30, 2.7um, 3 x 5mm, Guard Column 3pk C30 HALO C30 L62 2.7 um 3.0 mm 5 mm 160 A Guard
£525.97
92113-530 HALO 160A C30, 2.7um, 3 x 75mm C30 HALO C30 L62 2.7 um 3.0 mm 75 mm 160 A Column
£645.57
92114-630 HALO 160A C30, 2.7um, 4.6 x 100mm C30 HALO C30 L62 2.7 um 4.6 mm 100 mm 160 A Column
£697.03
92114-730 HALO 160A C30, 2.7um, 4.6 x 150mm C30 HALO C30 L62 2.7 um 4.6 mm 150 mm 160 A Column
£761.09
92114-230 HALO 160A C30, 2.7um, 4.6 x 20mm C30 HALO C30 L62 2.7 um 4.6 mm 20 mm 160 A Column
£547.33
92114-930 HALO 160A C30, 2.7um, 4.6 x 250mm C30 HALO C30 L62 2.7 um 4.6 mm 250 mm 160 A Column
£974.85
92114-330 HALO 160A C30, 2.7um, 4.6 x 30mm C30 HALO C30 L62 2.7 um 4.6 mm 30 mm 160 A Column
£547.33
92114-430 HALO 160A C30, 2.7um, 4.6 x 50mm C30 HALO C30 L62 2.7 um 4.6 mm 50 mm 160 A Column
£619.94
92114-130 HALO 160A C30, 2.7um, 4.6 x 5mm, Guard Column 3pk C30 HALO C30 L62 2.7 um 4.6 mm 5 mm 160 A Guard
£525.97
92114-530 HALO 160A C30, 2.7um, 4.6 x 75mm C30 HALO C30 L62 2.7 um 4.6 mm 75 mm 160 A Column
£645.57
  • C30 stationary phase that meets USP L62 designation
  • Ideal for hydrophobic, long chain, structurally related isomers
  • Typical applications include fat soluable vitamins (A, D, E, K), hydrophobic analytes, lipids, and carotenoids
  • Alternative alkyl phase with high shape selectivity
  • 100% aqueous compatible
  • Available with 2.7 µm superficially porous particles
  HALO® C30
Bonded Phase C30
Particle Type Fused-Core®
Particle Size 2.7 µm
Pore Size 160 Å
Endcapped Yes
Low pH/Temperature Limit 2/60°C
High pH/Temperature Limit 9/40°C
Pressure Limit 600 bar
Hardware Stainless Steel
USP Designation L62
HALO C30 Flyer (1.40 MB)
Isomers have met their match with HALO® C30 columns
HALO Catalogue (11.13 MB)
A better path to separations with Fused-Core®
HALO® Quality Brochure (10.81 MB)
Pioneering Fused-Core® Technology since 2005 - a commitment to innovation, quality and experience
HALO® Method Conversion Guidebook (1.53 MB)
How to take advantage of superficially porous particles for method improvements
HALO® Selectivity Guidebook (10.95 MB)
Guidebook on reversed phase chemistries and utilizing selectivity for HPLC separations
HALO® Guard Column Flyer (1.99 MB)
HALO® guard columns provide optimum protection for your HALO® HPLC and UHPLC column without sacrificing column efficiency
© 2024 Element Materials Technology