large image
Loading...

Captiva EMR-Lipid

Captiva EMR-Lipid from Agilent Technologies

Captiva EMR–Lipid provides highly selective and efficient lipid/matrix removal without unwanted analyte loss. The novel EMR-Lipid technology removes lipids based on a combination of size exclusion and hydrophobic interaction. Effective lipid removal assures minimal ion suppression of target analytes, which significantly improves method reliability and ruggedness.

The 96-well plate and 1 mL cartridge formats contain a solvent retention frit, which allows solvent-first in-well protein precipitation which streamlines sample preparation and the improved filter design gives easy flow with vacuum or positive pressure.

The 3 mL and 6 mL cartridge formats allow gravity flow with the absence of solvent retention frits and are easy to use.

Part Number Short Description Bed Mass SPE Format Price Qty
5190-1003 Captiva EMR-Lipid 300mg/3mL Cartridge, 100pk 300 mg Cartridge
£239.00
5190-1002 Captiva EMR-Lipid 40mg/1mL Cartridge, 100pk 40 mg Cartridge
£182.00
5190-1004 Captiva EMR-Lipid 600mg/6mL Cartridge, 50pk 600 mg Cartridge
£282.00
5190-1000 Captiva EMR-Lipid 96 Well Plate 40mg, 1pk 40 mg 96-Well Plate
£169.00
5190-1001 Captiva EMR-Lipid 96 Well Plate 40mg, 5pk 40 mg 96-Well Plate
£771.00
  • Highly selective and efficient lipid removal: the unique EMR-Lipid mechanism combines size exclusion and hydrophobic interactions between the sorbent and the long aliphatic chain of lipids
  • Clog-free operation: advanced filter design and construction technology ensures an easy flow
  • Time savings and improved precision: A protein crash solvent retention frit in 1 mL and 96-well plate formats promotes a streamlined, automatable in-well protein precipitation workflow
Captiva EMR Brochure (339.12 kB)
Minimize lipids and maximize recovery using Agilent Captiva EMR-Lipid 96-well plates and 1, 3, and 6 mL cartridges
Captiva EMR Method Guide for 96-well Plates and 1 mL Cartidges (507.88 kB)

General instructions for using the Captiva EMR 96-well plates and 1 mL cartridges

Captiva EMR Method Guide for 3 mL and 6 mL Cartridges (574.75 kB)

General instructions for using Captiva EMR 3 mL and 6 mL cartridges

Captiva EMR White Paper (1.37 MB)

White Paper discussing lipids and the hidden dangers of suboptimal matrix removal

Captiva EMR Infographic (1.12 MB)

Infographic highlighting productivity increase by using Captiva EMR-Lipid for sample preparation

Captiva Filtration Portfolio Brochure (1.08 MB)

Overview of the Agilent Captiva sample preparation filtration portfolio

Copyright © 2021 Crawford Scientific