Agilent MS Certified Liners
Agilent MS Certified Split and Splitless Liners are manufactured and tested to our highest level of scrutiny to assure reproducibility. We have built years of experience into the MS Certified Liners to provide the quality and consistency needed for critical applications, especially those using esterification agents for trace level analysis such as toxicology or drugs of abuse applications.
- Geometrical dimensions and tolerances of the glass are controlled by Statistical Process Control (SPC) with 100% Go-No-Go check.
- Glass wool is pre-qualified with mass spectrometry, then inserted using a unique manufacturing procedure to improve reproducibility.
- Deactivated MS Certified Liners are treated with Agilent's proven proprietary deactivation process developed to last longer than other commercially available treatment.
- Random samples of MS Certified Liners are tested using both FID and MSD analysis of challenging probes to evaluate acid/base deactivation, response linearity, peak symmetry, and bleed and background noise.
- Each Agilent MS Certified Liner is traceable by the lot codes silk screened on the liner
|
| Description |
Volume (ul) |
ID (mm) |
Pack Size |
Part Number |
| |
| Split Inlet Liners |
| Single taper, MS certified liner with restriction to hold glass wool |
900 |
4 |
1 |
5188-6576 |
| Straight, MS certified liner with glass wool |
900 |
4 |
1 |
5188-6574 |
900 |
4 |
5 |
5188-6569 |
| Splitless Inlet Liners |
| Single taper, MS certified liner with glass wool |
900 |
4 |
1 |
5188-6568 |
900 |
4 |
5 |
5188-6567 |
900 |
4 |
25 |
5188-6566 |
| |
Splitless Inlet Liners
Agilent's proprietary deactivation is important for splitless liners because of the longer sample/liner contact time in splitless mode. When deciding between a liner with or without glass wool, choose a liner without glass wool if your sample contains non-volatiles or analytes within a wide boiling range. For unknown samples, use a liner without glass wool to avoid loss of active or labile compounds. Agilent recommends first trying a liner without glass wool; use glass wool as a second choice. |
| Description |
Volume (ul) |
ID (mm) |
Pack Size |
Part Number |
| |
 |
Single taper, deactivated |
900 |
4 |
1 |
5181-3316 |
5 |
5183-4695 |
25 |
5183-4696 |
| Single taper, inert |
900 |
4 |
1 |
5181-3316i |
|
Single taper, glass wool, deactivated |
900 |
4 |
1 |
5062-3587 |
5 |
5183-4693 |
25 |
5183-4694 |
|
Single taper, glass wool, deactivated MS certified
|
900 |
4 |
1 |
5188-6568 |
|
Double taper, deactivated
|
800 |
4 |
1 |
5181-3315 |
5 |
5183-4705 |
25 |
5183-4706 |
| |
|
Straight, deactivated, quartz
|
250 |
2 |
1 |
5181-8818 |
5 |
5183-4703 |
25 |
5183-4704 |
|
Straight, non-deactivated, quartz
|
250 |
2 |
1 |
18740-80220 |
5 |
5183-4707 |
25 |
5183-4708 |
|
Straight, non-deactivated
|
990 |
4 |
1 |
210-3003 |
5 |
210-3003-5 |
| |
Split Inlet Liners
Agilent Single Taper Split Liners are made to strict dimension specifications for optimal inlet performance and feature the tightest tolerances for OD, ID, taper, and glass wool placement. For ease of use and reproducibility, the liners have a positioning bead, a restriction to secure the position of the glass wool, and a feature to consistently self-position to the recommended height. The liners also feature Agilent's proprietary deactivation. |
| Description |
Volume (ul) |
ID (mm) |
Pack Size |
Part Number |
|
 |
Single taper, glass wool, deactivated (general purpose) |
870 |
4 |
1 |
5183-4711 |
5 |
5183-4712 |
25 |
5183-4713 |
 |
Single taper, glass wool, deactivated, low pressure drop |
870 |
4 |
1 |
5183-4647 |
5 |
5183-4701 |
25 |
5183-4702 |
|
Straight, deactivated glass wool |
990 |
4 |
1 |
19251-60540 |
5 |
5183-4691 |
25 |
5183-4692 |
|
Straight, with cup (for manual injections) |
800 |
4 |
1 |
18740-80190 |
5 |
5183-4699 |
25 |
5183-4700 |
|
Straight, with cup, glass wool and packing (for manual injections, not recommended for use with EPC) |
800 |
4 |
1 |
18740-60840 |
5 |
5183-4697 |
25 |
5183-4698 |
| |
Direct Inlet Liners
Agilent's Direct Connect Liners provide maximum recovery and minimal decomposition of active compounds for methods requiring splitless injection, such as EPA 8270. They are best for relatively clean samples containing active analytes, such as water extracts. The liners directly connect with the column, similar to press-fit connectors, to aid complete transfer of sample onto the column, eliminating the problem of inlet discrimination and further increasing sensitivity. |
| Description |
Volume (ul) |
ID (mm) |
Pack Size |
Part Number |
| |
|
Straight, non-deactivated (for gas samples, headspace, or purge & trap)
|
140 |
1.5 |
1 |
18740-80200 |
5 |
5183-4709 |
25 |
5183-4710 |
| |
Direct Connect Liners
Agilent's Direct Connect Liners provide maximum recovery and minimal decomposition of active compounds for methods requiring splitless injection, such as EPA 8270. They are best for relatively clean samples containing active analytes, such as water extracts. The liners directly connect with the column, similar to press-fit connectors, to aid complete transfer of sample onto the column, eliminating the problem of inlet discrimination and further increasing sensitivity. |
| Description |
Pack Size |
Part Number |
| |
|
|
|
Single taper, Agilent proprietary deactivation |
1 |
G1544-80730 |
| Dual taper, Agilent proprietary deactivation |
1 |
G1544-80700 |
| Single taper, deactivated, inert |
1 |
G1544-80731 |
| |
Focus Liner
Agilent's Direct Connect Liners provide maximum recovery and minimal decomposition of active compounds for methods requiring splitless injection, such as EPA 8270. They are best for relatively clean samples containing active analytes, such as water extracts. The liners directly connect with the column, similar to press-fit connectors, to aid complete transfer of sample onto the column, eliminating the problem of inlet discrimination and further increasing sensitivity. |
| Description |
Pack Size |
Part Number |
| |
|
|
 |
Deactivated with glass wool, 4 mm ID, 6.3 mm x 78.5 mm |
5 |
210-4004-5 |
 |
Tapered, deactivated with glass wool, 4 mm ID, 6.3 mm x 78.5 mm |
5 |
210-4022-5 |
| |
Helix Liners
Helix liners approximate the benefit of glass wool without the activity. The deactivated glass spiral gives surface area without glass wool's active sites to vaporize and mix sample before getting onto the column, and prevents sample from splashing onto the bottom of liner and seal. Helix liners are recommended for slower injection speeds. |
| Description |
Part Number |
| |
|
|
Helix open ended, deactivated |
5188-5396 |
| Helix double taper, deactivated |
5188-5398 |
| Helix single taper, deactivated |
5188-5397 |