Crawford Scientific
Javascript DHTML Drop Down Menu Powered by dhtml-menu-builder.com
 
  Product Information
  Parts and Pricing
you’re in > Products > Manufacturers > Agilent Technologies > GC Instrument Spares > Liners
 

Agilent Technologies GC Liners

Agilent Technologies GC Inlet Liner
 

Crawford Scientific offers a complete selection of Agilent Technologies GC split and splitless inlet liners that deliver consistent quality so you can get consistent results.


Unlike other manufacturer’s liners, Agilent liners are built to Agilent’s precise inlet tolerances which helps ensure optimal dimensional accuracy and inertness toward demanding compounds. In addition, silk screened part numbers and lot number on liners make identification and re-ordering easier for you.

 

There are four choices of liner available

 
 

Agilent MS Certified Liners
Agilent MS Certified Split and Splitless Liners are manufactured and tested to our highest level of scrutiny to assure reproducibility. We have built years of experience into the MS Certified Liners to provide the quality and consistency needed for critical applications, especially those using esterification agents for trace level analysis such as toxicology or drugs of abuse applications.

  • Geometrical dimensions and tolerances of the glass are controlled by Statistical Process Control (SPC) with 100% Go-No-Go check.
  • Glass wool is pre-qualified with mass spectrometry, then inserted using a unique manufacturing procedure to improve reproducibility.
  • Deactivated MS Certified Liners are treated with Agilent's proven proprietary deactivation process developed to last longer than other commercially available treatment.
  • Random samples of MS Certified Liners are tested using both FID and MSD analysis of challenging probes to evaluate acid/base deactivation, response linearity, peak symmetry, and bleed and background noise.
  • Each Agilent MS Certified Liner is traceable by the lot codes silk screened on the liner
Description Volume (ul) ID (mm) Pack Size Part Number
 
Split Inlet Liners
Single taper, MS certified liner with restriction to hold glass wool
900
4
1
5188-6576
Straight, MS certified liner with glass wool
900
4
1
5188-6574
900
4
5
5188-6569
Splitless Inlet Liners
Single taper, MS certified liner with glass wool
900
4
1
5188-6568
900
4
5
5188-6567
900
4
25
5188-6566
 
Splitless Inlet Liners
Agilent's proprietary deactivation is important for splitless liners because of the longer sample/liner contact time in splitless mode. When deciding between a liner with or without glass wool, choose a liner without glass wool if your sample contains non-volatiles or analytes within a wide boiling range. For unknown samples, use a liner without glass wool to avoid loss of active or labile compounds. Agilent recommends first trying a liner without glass wool; use glass wool as a second choice.
Description Volume (ul) ID (mm) Pack Size Part Number
 
Agilent Technologies Single taper deactivated liner Single taper, deactivated
900
4
1
5181-3316
5
5183-4695
25
5183-4696
Single taper, inert
900
4
1
5181-3316i
Agilent Technologies Single Glass Wool Deactivated liner Single taper, glass wool, deactivated
900
4
1
5062-3587
5
5183-4693
25
5183-4694
Agilent Technologies Single Glass Wool Deactivated liner Single taper, glass wool, deactivated MS certified
900
4
1
5188-6568
Agilent Technologies Double taper deactivated liner Double taper, deactivated
800
4
1
5181-3315
5
5183-4705
25
5183-4706
 
Agilent Technologies Straight deactivated quartz liner Straight, deactivated, quartz
250
2
1
5181-8818
5
5183-4703
25
5183-4704
Agilent Technologies Straight non-deactivated quartz liner Straight, non-deactivated, quartz
250
2
1
18740-80220
5
5183-4707
25
5183-4708
Agilent Technologies Straight non-deactivated liner Straight, non-deactivated
990
4
1
210-3003
5
210-3003-5
 
Split Inlet Liners
Agilent Single Taper Split Liners are made to strict dimension specifications for optimal inlet performance and feature the tightest tolerances for OD, ID, taper, and glass wool placement. For ease of use and reproducibility, the liners have a positioning bead, a restriction to secure the position of the glass wool, and a feature to consistently self-position to the recommended height. The liners also feature Agilent's proprietary deactivation.
Description Volume (ul) ID (mm) Pack Size Part Number

 

Agilent Technologies Single taper glass wool deactivated (general purpose) liner Single taper, glass wool, deactivated (general purpose)
870
4
1
5183-4711
5
5183-4712
25
5183-4713
Agilent Technologies Single taper glass wool deactivated low pressure drop  liner Single taper, glass wool, deactivated, low pressure drop 
870
4
1
5183-4647
5
5183-4701
25
5183-4702
Agilent Technologies Straight deactivated glass wool liner Straight, deactivated glass wool 
990
4
1
19251-60540
5
5183-4691
25
5183-4692
Agilent Technologies Straight with cup (for manual injections) liner Straight, with cup (for manual injections) 
800
4
1
18740-80190
5
5183-4699
25
5183-4700
Agilent Technologies Straight with cup glass wool and packing (for manual injections, not recommended for use with EPC) liner Straight, with cup, glass wool and packing (for manual injections, not recommended for use with EPC) 
800
4
1
18740-60840
5
5183-4697
25
5183-4698
 
Direct Inlet Liners
Agilent's Direct Connect Liners provide maximum recovery and minimal decomposition of active compounds for methods requiring splitless injection, such as EPA 8270. They are best for relatively clean samples containing active analytes, such as water extracts. The liners directly connect with the column, similar to press-fit connectors, to aid complete transfer of sample onto the column, eliminating the problem of inlet discrimination and further increasing sensitivity.  
Description Volume (ul) ID (mm) Pack Size Part Number
 
Agilent Technologies Straight non-deactivated (for gas samples, headspace, or purge & trap)  Straight, non-deactivated (for gas samples, headspace, or purge & trap) 
140
1.5
1
18740-80200
5
5183-4709
25
5183-4710
 
Direct Connect Liners
Agilent's Direct Connect Liners provide maximum recovery and minimal decomposition of active compounds for methods requiring splitless injection, such as EPA 8270. They are best for relatively clean samples containing active analytes, such as water extracts. The liners directly connect with the column, similar to press-fit connectors, to aid complete transfer of sample onto the column, eliminating the problem of inlet discrimination and further increasing sensitivity.  
Description Pack Size Part Number
     
Agilent Direct Connect Liner Single taper, Agilent proprietary deactivation 1
G1544-80730
Dual taper, Agilent proprietary deactivation 1
G1544-80700
Single taper, deactivated, inert 1
G1544-80731
 
Focus Liner
Agilent's Direct Connect Liners provide maximum recovery and minimal decomposition of active compounds for methods requiring splitless injection, such as EPA 8270. They are best for relatively clean samples containing active analytes, such as water extracts. The liners directly connect with the column, similar to press-fit connectors, to aid complete transfer of sample onto the column, eliminating the problem of inlet discrimination and further increasing sensitivity.  
Description Pack Size Part Number
     
Focus Liner Deactivated with glass wool, 4 mm ID, 6.3 mm x 78.5 mm 5
210-4004-5
Focus liner Tapered, deactivated with glass wool, 4 mm ID, 6.3 mm x 78.5 mm 5
210-4022-5
 
Helix Liners
Helix liners approximate the benefit of glass wool without the activity. The deactivated glass spiral gives surface area without glass wool's active sites to vaporize and mix sample before getting onto the column, and prevents sample from splashing onto the bottom of liner and seal. Helix liners are recommended for slower injection speeds. 
Description Part Number
   
Agilent Helix Liners Helix open ended, deactivated
5188-5396
Helix double taper, deactivated
5188-5398
Helix single taper, deactivated
5188-5397
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

top


 
 
©Crawford Scientific 2013