Agilent NOVEMA Max columns are tailored for aqueous SEC analysis and are particularly suited to cationic polymers such as polymeric quaternary ammonium compounds, poly(DADMAC), polyvinylpyridine, chitosan, and poly(ethylene imine), with molecular weights spanning from 100 to 30,000,000 Da. Available in two particle sizes and different porosities as well as linear/mixed-bed options, NOVEMA Max columns offer flexibility for a variety of applications. These columns conform to USP L23 standards and tolerate high buffer concentrations, pH range from 2 to 12, temperatures up to 80°C, and organic solvents, accommodating up to 100% methanol or acetonitrile.

Part Number Product Description Price Qty
product image

Features

  • NOVEMA Max are packed with highly porous particles of a modified acrylate copolymer
  • Suitable for the aqueous SEC separation of cationic polymers
  • Meets USP L23 classification
  • Compatible with a wide range of aqueous eluents with optimum performance when used with eluents that have a pH in the range 1.5 to 7.0
  • Shipped in water with 7.5 mM sodium azide to prevent microbial growth
  • Excellent separation efficiency obtained by narrow particle size distribution and optimised frit technology
  • Columns produced under DIN EN ISO 9001 quality standards
  • Each column individually tested with a certificate of analysis available
  • Guard columns protect and extend the lifetime of analytical columns
  • NOVEMA Max Lux is recommended for light scattering detection

Specification

  NOVEMA Max
Pore Size 30 Å 100 Å 1000 Å 3000 Å Linear S Linear M Linear Ultrahigh
Particle Type Individual Pore Size Individual Pore Size Individual Pore Size Individual Pore Size Mixed Pore Size Mixed Pore Size Mixed Pore Size
Molecular Weight Lower Limit 100 Da 1000 Da 1000 Da 10,000 Da 100 Da 200 Da 500 Da
Molecular Weight Upper Limit 30,000 Da 100,000 Da 1,000,000 Da 3,000,000 Da 100,000 Da 1,000,000 Da 30,000,000 Da
Particle Size 5 µm, 20 µm 5 µm, 10 µm, 20 µm 5 µm, 10 µm, 20 µm 10 µm, 20 µm 5 µm, 20 µm 5 µm, 20 µm 10 µm
Temperature Limit 80°C 80°C 80°C 80°C 80°C 80°C 80°C
Shipping Solvent Water Water Water Water Water Water Water