We are now trading as Crawford Scientific

Agilent Intuvo Ultra Inert GC Columns

As part of the Agilent J&W Ultra Inert GC column family, Ultra Inert Intuvo GC columns (compatible only with the Intuvo 9000 GC System) push industry standards for consistent column inertness and exceptionally low column bleed, resulting in lower detection limits and more accurate data for difficult analytes.

Offered in a wide range of stationary phase polarities (non, low, mid, and high polarity), each Ultra Inert Intuvo GC column is tested with the industry’s most demanding test probe mixture, and a performance summary sheet is shipped with each column.

Part Number Product Description Price Qty
product image

Features

  • Wide selection of stationary phase polarities are available (non, low, mid, and high polarity)
  • Strict quality control specifications and testing ensure long-term column-to-column performance and accurate separations
  • Part of an optimized GC flow path with Agilent Ultra Inert Liners, low-bleed septa, certified vials and gas clean filters

“ms” column have very low bleed characteristics, and are ideal for GC/MS applications. Low bleed stationary phases reduces column contribution to background noise, resulting in an improved signal-to-noise ratio for better sensitivity and mass spectral integrity.


Compatible only with the Agilent Intuvo 9000 GC System

All Intuvo GC columns include a Smart Key, which enables the system to immediately identify the column configuration and temperature limits (including column part and serial numbers), as well as tracking the use of the column.

Specification

DB-1ms UI Temperature Specifications

ID 0.25 – 0.32 mm
Length 15 – 60 m
Film 0.25 µm
Temperature Limits -60 – 340/360°C

 

DB-5ms UI Temperature Specifications

ID 0.18 – 0.32 mm
Length 15 – 60 m
Film 0.18 – 0.50 µm
Temperature Limits -60 – 325/350°C

 

DB-35ms UI Temperature Specifications

ID 0.18 – 0.32 mm
Length 15 – 30 m
Film 0.18 – 0.25 µm
Temperature Limits 50 – 340/360°C

 

DB-624 UI Temperature Specifications

ID 0.25 mm
Length 30 m
Film 1.40 µm
Temperature Limits -20 – 260°C

 

DB-Select 624 UI Temperature Specifications

ID 0.25 – 0.32 mm
Length 15 – 30 m
Film 1.40 – 1.80 µm
Temperature Limits 40 – 260/260°C

 

DB-WAX UI Temperature Specifications

ID 0.18 – 0.25 mm
Length 5 – 20 m
Film 0.18 – 0.25 µm
Temperature Limits 20 – 250/260°C

 

DB-FATWAX UI Temperature Specifications

ID 0.18 – 0.32 mm
Length 20 – 30 m
Film 0.18 – 0.25 µm
Temperature Limits 20 – 250/260°C

 

HP-1ms UI Temperature Specifications

ID 0.18 – 0.32 mm
Length 5 – 30 m
Film 0.18 – 0.25 µm
Temperature Limits -60 – 325/350°C

 

HP-5ms UI Temperature Specifications

ID 0.18 – 0.32 mm
Length 10 - 60 m
Film 0.18 – 1.00 µm
Temperature Limits -60 – 325/350°C

 

 

Literature

Full range of Agilent Technologies GC columns and applications

An ordering guide showing the innovative range of supplies and fittings for the Agilent Intuvo GC system
Detect every peak and minimize degradative buildup in your GC flow path
Optimising your GC flow path for inertness
For best trace level analysis, maintain your inert flow path with Agilent inert flow path components

Agilent Product Manager's recommendations: top supplies to optimize your Intuvo GC-MS workflow