Agilent HP-PLOT Al2O3 GC Columns
Agilent J&W HP-PLOT Al2O3 KCl is the least polar alumina phase and is deactivated with KCl. It is the standard column choice for light hydrocarbon analysis, particularly C1 – C8 hydrocarbon isomers. It is excellent for quantitation of dienes, especially propadiene and butadiene from ethylene and propylene streams.
Agilent J&W HP-PLOT Al2O3 S is the middle polarity alumina phase and is deactivated with sodium sulfate. It is the standard column choice for light hydrocarbon analysis, particularly C1 – C8 hydrocarbon isomers. It is excellent for resolving acetylene from butylene and isobutane.
Agilent J&W HP-PLOT Al2O3 M is the most polar alumina phase and is deactivated by a proprietary method. It is a good general use column for light hydrocarbon analysis for C1 – C8 hydrocarbon isomers. It is good for resolving acetylene from butane and propylene from isobutane.
HP-PLOT Al2O3 KCl
- Least polar Alumina phase
- Aluminum oxide deactivated with KCl
- Standard column choice for light hydrocarbons analysis - C1 – C8 hydrocarbon isomers
- Low retention of olefins relative to comparable paraffin
- Excellent for quantitation of dienes, especially propadiene and butadiene from ethylene and propylene streams
- Recommended phase for many ASTM methods
- Preferred KCl deactivated Alumina
Similar Phases: Rt-Alumina PLOT, Alumina PLOT, Al2O3/KCl, AB-PLOT Al2O3 KCl, AT-Alumina
HP-PLOT Al2O3 S
- Middle range of polarity for Alumina phases
- Aluminum oxide deactivated with sodium sulfate
- Excellent general use column for light hydrocarbon analysis – C1 – C8 hydrocarbon isomers
- Best for resolving acetylene from butane and propylene from isobutane
Similar Phases: Al2O3/Na2SO4, Rt-Alumina PLOT, Alumina PLOT, Rt-Alumina BOND/Na2SO4, MXT-Alumina BOND/Na2SO4, Alumina sulfate PLOT, AT-Alumina
HP-PLOT Al2O3 M
- Most polar Alumina phase (similar to GS-Alumina)
- Aluminiun oxide deactivated with proprietary deactivation
- Good general use column for analysis of C1 – C8 hydrocarbon isomers
- Excellent for resolving acetylene from butane and propylene from isobutane
Similar Phases: AB-PLOT Al2O3 M, BGB-PLOT Al2O3 M, AT-Alumina
A 7 inch cage is the most common GC column format, compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems, and all non-Agilent GC systems with a similarly sized oven. The 5 inch cage format is designed for smaller GC ovens e.g. for the Agilent GC 6850.
HP-PLOT Al2O3 KCl Temperature Specifications
ID | 0.25 – 0.53 mm |
Length | 30 – 50 m |
Film | 5 – 15 µm |
Temperature Limits | -60 – 200°C |
HP-PLOT Al2O3 S Temperature Specifications
ID | 0.53 mm |
Length | 15 – 50 m |
Film | 15 µm |
Temperature Limits | -60 – 200°C |
HP-PLOT Al2O3 M Temperature Specifications
ID | 0.53 mm |
Length | 30 – 50 m |
Film | 15 µm |