large image
Loading...

Agilent VF-5ht UltiMetal GC Columns

Agilent J&W VF-5ht UltiMetal improves the analysis of high-boiling compounds through low-bleed performance, even at high temperatures. Based on ultra-low-bleed technology, VF-5ht provides unmatched selectivity, sensitivity, and accuracy for the analysis of high molecular weight compounds.

This phase is also available in standard fused silica material: VF-5ht.

Part Number Short Description Film Thickness Phase ID Length Type Material Price Qty
CP9090 VF-5ht, UltiMetal, 15m x 0.25mm x 0.1um 0.10 um VF-5ht 0.25 mm 15 m 7 inch UltiMetal
£515.00
CP9091 VF-5ht, UltiMetal, 15m x 0.25mm x 0.1um, + 2m Retention Gap 0.10 um VF-5ht 0.25 mm 15 m 7 inch UltiMetal
£754.00
CP9094 VF-5ht, UltiMetal, 15m x 0.32mm x 0.1um 0.10 um VF-5ht 0.32 mm 15 m 7 inch UltiMetal
£544.00
CP9095 VF-5ht, UltiMetal, 15m x 0.32mm x 0.1um, + 2m Retention Gap 0.10 um VF-5ht 0.32 mm 15 m 7 inch UltiMetal
£783.00
CP9092 VF-5ht, UltiMetal, 30m x 0.25mm x 0.1um 0.10 um VF-5ht 0.25 mm 30 m 7 inch UltiMetal
£843.00
CP9093 VF-5ht, UltiMetal, 30m x 0.25mm x 0.1um, + 2m Retention Gap 0.10 um VF-5ht 0.25 mm 30 m 7 inch UltiMetal
£1,082.00
CP9092I5 VF-5ht, UltiMetal, 30m x 0.25mm x 0.1um, 5in cage 0.10 um VF-5ht 0.25 mm 30 m 5 inch UltiMetal
£946.00
CP9096 VF-5ht, UltiMetal, 30m x 0.32mm x 0.1um 0.10 um VF-5ht 0.32 mm 30 m 7 inch UltiMetal
£899.00
CP9097 VF-5ht, UltiMetal, 30m x 0.32mm x 0.1um, + 2m Retention Gap 0.10 um VF-5ht 0.32 mm 30 m 7 inch UltiMetal
£1,138.00
  • Enhanced stability improves column longevity and reduces downtime
  • Superior detector performance provides improved detection limits
  • Ultra low bleed at high temperatures for analysis of high-boiling compounds
  • Optimised sensitivity and accuracy for analysis of high molecular weight compounds
  • Identical selectivity as VF-5ms (bleed spec of 30m x 0.25mm column is < 5pA at 400°C)
  • UltiMetal technology renders the stainless steel inert and enhances bonding of the stationary phase for improved column lifetime and excellent peak shape
  • Tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency
  • Performance Summary shipped with each column

Similar Phases: ZB-5ht, Rxi-5ht

 

This phase is also available in standard fused silica material: VF-5ht.


 

A 7 inch cage is the most common GC column format, compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems, and all non-Agilent GC systems with a similarly sized oven. The 5 inch cage format is designed for smaller GC ovens e.g. for the Agilent GC 6850.

VF-5ht UltiMetal Temperature Specifications

ID 0.25 – 0.32 mm
Length 10 – 30 m
Film 0.10 µm
Temperature Limits -60 – 430/450 °C 

 

Agilent GC Column Brochure (11.67 MB)

Full range of Agilent Technologies GC columns and applications

© 2024 Element Materials Technology