large image
Loading...

Agilent HP-PLOT Q GC Columns

Agilent J&W HP-PLOT Q is a bonded polystyrene-divinylbenzene (DVB) column specially developed for the separation of targeted non-polar and polar compounds, including hydrocarbons (natural gas, refinery gas, ethylene, propylene, all C1 – C3 isomers); CO2, methane, air/CO, and water; polar solvents (methanol, acetone, methylene chloride, alcohols, ketones, aldehydes, esters); and sulfur compounds (H2S, mercaptans, COS).

Part Number Short Description Film Thickness Phase ID Length Type Material Price Qty
19091P-QO3 HP-PLOT Q, 15m x 0.32mm x 20um 20 um HP-PLOT Q 0.32 mm 15 m 7 inch Fused Silica
£492.00
19091P-QO3PT HP-PLOT Q, 15m x 0.32mm x 20um, with 2PT 20 um HP-PLOT Q 0.32 mm 15 m 7 inch Fused Silica
£566.00
19095P-QO3 HP-PLOT Q, 15m x 0.53mm x 40um 40 um HP-PLOT Q 0.53 mm 15 m 7 inch Fused Silica
£506.00
19095P-QO3E HP-PLOT Q, 15m x 0.53mm x 40um, 5in cage 40 um HP-PLOT Q 0.53 mm 15 m 5 inch Fused Silica
£567.00
19095P-QO3PT HP-PLOT Q, 15m x 0.53mm x 40um, with 2PT 40 um HP-PLOT Q 0.53 mm 15 m 7 inch Fused Silica
£582.00
19091P-QO4 HP-PLOT Q, 30m x 0.32mm x 20um 20 um HP-PLOT Q 0.32 mm 30 m 7 inch Fused Silica
£684.00
19091P-QO4E HP-PLOT Q, 30m x 0.32mm x 20um, 5in cage 20 um HP-PLOT Q 0.32 mm 30 m 5 inch Fused Silica
£767.00
19091P-QO4PT HP-PLOT Q, 30m x 0.32mm x 20um, with 2PT 20 um HP-PLOT Q 0.32 mm 30 m 7 inch Fused Silica
£787.00
19095P-QO4 HP-PLOT Q, 30m x 0.53mm x 40um 40 um HP-PLOT Q 0.53 mm 30 m 7 inch Fused Silica
£753.00
19095P-QO4E HP-PLOT Q, 30m x 0.53mm x 40um, 5in cage 40 um HP-PLOT Q 0.53 mm 30 m 5 inch Fused Silica
£844.00
19095P-QO4PT HP-PLOT Q, 30m x 0.53mm x 40um, with 2PT 40 um HP-PLOT Q 0.53 mm 30 m 7 inch Fused Silica
£866.00
  • Bonded polystyrene-divinylbenzene based column
  • A PLOT column with polarity between Porapak-Q and Porapak-N
  • Excellent column for C1 – C3 isomers and Alkanes to C12, CO2, methane, air/CO, oxygenated compounds, sulfur compounds, and solvents
  • A PLOT column to replace packed gas-solid columns
  • Separates ethane, ethylene and ethyne (acetylene)
  • Improved resolution in less time than conventional packed columns, minimal conditioning time required - 1 hour
  • Preferred "Q" column due to its robust nature

Similar Phases: Rt-QPLOT, SupelQ PLOT


 

A 7 inch cage is the most common GC column format, compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems, and all non-Agilent GC systems with a similarly sized oven. The 5 inch cage format is designed for smaller GC ovens e.g. for the Agilent GC 6850.

HP-PLOT Q Temperature Specifications

ID 0.32 – 0.53mm
Length 15 – 30 m
Film 20 – 40 µm
Temperature Limits -60 – 270/290°C
Agilent GC Column Brochure (11.67 MB)

Full range of Agilent Technologies GC columns and applications

Voids in PLOT Columns (65.06 kB)
What causes the spots on the PLOT columns?
© 2024 Element Materials Technology