Agilent 5975T LTM Column Module GC Columns
Agilent J&W 5975T LTM column modules are designed specifically for Agilent 5975T GC/MS systems. These modules include an integrated 3 in LTM capillary column toroid assembly with heated transfer lines, cooling fan assembly, and sheet-metal enclosure. LTM column modules offers faster heating and cooling for more rapid analytical cycle times than standard air-bath GC oven techniques.
- Suitable for majority of Agilent J&W Capillary GC columns (30m maximum length)
- Rapid temperature programming rates of up to 1800°C/min achievable
- Fast cooling times - less than one minute for some configurations
- Excellent retention time repeatability and excellent separation performance, comparable to conventional GC
- Ability to run up to four column modules simultaneously, using different temperature programs
- Works with 7890/6890 GC injectors and detectors for little change to your existing methods
- Compatible with Agilent Capillary Flow Technology, for multi-dimensional GC
“ms” column have very low bleed characteristics, and are ideal for GC/MS applications. Low bleed stationary phases reduces column contribution to background noise, resulting in an improved signal-to-noise ratio for better sensitivity and mass spectral integrity.
5975T LTM Column Module GC Column Temperature Specifications:
Stationary Phase | Temperature Limits |
DB-1 | -60 – 325/350°C |
DB-1ms | -60 – 340/350°C |
DB-5ms | -60 – 325/350°C |
DB-5ms UI | -60 – 325/350°C |
DB-5ht | -60 – 400°C |
HP-5ms | -60 – 325/350°C |
HP-5ms UI | -60 – 325/350°C |
DB-VRX | -10 – 260°C |
DB-17ms | 40 – 320/340°C |
DB-1701 | -20 – 280/300°C |
DB-35ms | 50 – 340/360°C |
DB-624 | -20 – 280°C |
DB-225ms | 40 – 240°C |
DB-FFAP | 40 – 250°C |
DB-1 GC Columns
- Wide range of applications- excellent choice for general purpose use
- 100% dimethylpolysiloxane
- Non-Polar
- Equivalent to USP Phase G2
- Low bleed
- Bonded, cross-linked and solvent rinsable
- Temperature Limits: -60 – 325/350°C
Similar Phases: HP-1, CP-Sil 5 CB, OV-1, Rtx-1, ZB-1, SPB-1, Equity 1, BP-1, OPTIMA 1, 007-1, SP-2100, AT-1, MDN-1, OV-101, SE-30
DB-1ms GC Columns
- 100% dimethylpolysiloxane
- Non-Polar
- Equivalent to USP Phase G2
- Identical selectivity to DB-1
- Very low bleed characteristics, ideal for GC/MS
- Excellent inertness for acids and bases
- Bonded, cross-linked and solvent rinsable
- Temperature Limits: -60 – 340/350°C
Similar Phases: HP-1, HP-1ms, VF-1ms, CP-Sil 5 CB, CP-Sil 5 CB-ms, OV-1, OV-1ms, Rtx-1, Rxi-1ms, ZB-1, ZB-1ms, SPB-1, SLB-1ms, Equity 1, BP-1, OPTIMA 1, OPTIMA 1 MS, 007-1, 007-1MS, SP-2100, AT-1, AT-1ms, MDN-1, OV-101, SE-30
DB-5ms GC Columns
- Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane
- Low Polarity
- Close equivalent to USP Phase G27
- Identical selectivity to DB-5
- Very low bleed characteristics, ideal for GC/MS
- Exact replacement of HP-5TA
- Bonded, cross-linked and solvent rinsable
- Temperature Limits: -60 – 325/350°C
Similar Phases: HP-5, HP-5ms, VF-5ms, CP-Sil 8 CB, CP-Sil 8 CB-ms, OV-5, OV-5ms, Rtx-5, Rtx-5ms, Rxi-5ms, Rxi-5Sil MS, ZB-5, ZB-5ms, ZB-5MSi, SPB-5, SLB-5ms, Equity 5, BP-5, OPTIMA 5, OPTIMA 5 MS, 007-5, 007-5MS, AT-5, AT-5ms, PTE-5, BPX-5, OV-73, SE-54
DB-5ms Ultra Inert GC Columns
- Tested with a demanding Ultra Inert test probe mixture
- Minimum compound adsorption or degradation
- Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane
- Low Polarity
- Close equivalent to USP Phase G27
- Identical selectivity to DB-5/DB-5ms
- Very low bleed characteristics, ideal for GC/MS
- Bonded, cross-linked and solvent rinsable
- Excellent inertness for active compounds
- Temperature Limits: -60 – 325/350°C
Similar Phases: HP-5, HP-5ms, VF-5ms, CP-Sil 8 CB, CP-Sil 8 CB-ms, OV-5, OV-5ms, Rtx-5, Rtx-5ms, Rxi-5ms, Rxi-5Sil MS, ZB-5, ZB-5ms, ZB-5MSi, SPB-5, SLB-5ms, Equity 5, BP-5, OPTIMA 5, OPTIMA 5 MS, 007-5, 007-5MS, AT-5, AT-5ms, PTE-5, BPX-5, OV-73, SE-54
DB-5ht GC Columns
- Specially processed for extended temperature limit of 400 °C
- Faster elution times for high boilers
- Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane
- Low Polarity
- Close equivalent to USP Phase G27
- Identical selectivity to DB-5/DB-5ms
- Bonded, cross-linked and solvent rinsable
- Temperature Limits: -60 – 400°C
Similar Phases: HP-5, HP-5ms, VF-5ms, VF-5ht, CP-Sil 8 CB, CP-Sil 8 CB-ms, OV-5, OV-5ms, Rtx-5, Rtx-5ms, Rxi-5ms, Rxi-5Sil MS, Rxi-5ht, ZB-5, ZB-5ms, ZB-5MSi, ZB-5HT inferno,SPB-5, SLB-5ms, Equity 5, BP-5, HT-5, OPTIMA 5, OPTIMA 5 MS, OPTIMA 5HT, 007-5, 007-5MS, 007-5HT, AT-5, AT-5ms, PTE-5, BPX-5, OV-73, SE-54
HP-5ms GC Columns
- (5%-phenyl)-methylpolysiloxane
- Low Polarity
- Equivalent to USP Phase G27
- Identical selectivity to HP-5
- Very low bleed characteristics, ideal for GC/MS
- Bonded, cross-linked and solvent rinsable
- Temperature Limits: -60 – 325/350°C
Similar Phases: HP-5, DB-5, DB-5ms, VF-5ms, CP-Sil 8 CB, CP-Sil 8 CB-ms, OV-5, OV-5ms, Rtx-5, Rtx-5ms, Rxi-5ms, Rxi-5Sil MS, ZB-5, ZB-5ms, ZB-5MSi, SPB-5, SLB-5ms, Equity 5, BP-5, OPTIMA 5, OPTIMA 5 MS, 007-5, 007-5MS, AT-5, AT-5ms, PTE-5, BPX-5, OV-73, SE-54
HP-5ms Ultra Inert GC Columns
- Excellent for trace level analysis of acids and bases, such as semivolatiles analysis
- (5%-phenyl)-methylpolysiloxane
- Low Polarity
- Equivalent to USP Phase G27
- Identical selectivity to HP-5/HP-5ms
- Very low bleed characteristics, ideal for GC/MS
- Bonded, cross-linked and solvent rinsable
- Excellent inertness for active compounds, including acidic and basic compounds
- Temperature Limits: -60 – 325/350°C
Similar Phases: HP-5, DB-5, DB-5ms, VF-5ms, CP-Sil 8 CB, CP-Sil 8 CB-ms, OV-5, OV-5ms, Rtx-5, Rtx-5ms, Rxi-5ms, Rxi-5Sil MS, ZB-5, ZB-5ms, ZB-5MSi, SPB-5, SLB-5ms, Equity 5, BP-5, OPTIMA 5, OPTIMA 5 MS, 007-5, 007-5MS, AT-5, AT-5ms, PTE-5, BPX-5, OV-73, SE-54
DB-VRX GC Columns
- Unique selectivity engineered for optimum resolution of volatiles analysis: U.S. EPA Methods 502.2, 524.2 and 8260
- Low Polarity
- Equivalent to USP Phase 53
- Bonded, cross-linked and solvent rinsable
- Temperature Limits: -10 – 260°C
Similar Phases: Rtx-VRX, Rtx-Volatiles, Rtx-VGC, 007-624, VOCOL, NON-PAKD, PE-Volatiles
DB-17ms GC Columns
- Excellent for the analysis of pesticides and other semivolatile analyses – best column for CLP pesticides
- Equivalent to (50%-phenyl)-methylpolysiloxane
- Mid Polarity
- Equivalent to USP Phase G3
- Very low bleed characteristics, ideal for GC/MS
- Identical selectivity to DB-17
- Exact replacement of HP-1701
- Bonded, cross-linked and solvent rinsable
- Excellent inertness for active compounds
- Temperature Limits: 40 – 320/340°C
Similar Phases: DB-17, DB-17ms, HP-17, HP-50+, VF-17ms, CP-Sil 24 CB, CP-Sil 24 CBms, OV-17, Rxi-17, Rxi-17Sil MS, Rtx-50, ZB-50, SPB-17, SPB-50, BPX50, OPTIMA 17, OPTIMA 17 MS, 007-17, 007-17MS, SP-2250, AT-50
DB-1701 GC Columns
- For enhanced analysis of pesticides, herbicides, TMS sugars, and aroclors
- (14%-cyanopropyl-phenyl)-methylpolysiloxane
- Low-Mid Polarity
- Equivalent to USP Phase G46
- Bonded, cross-linked and solvent rinsable
- Temperature Limits: -20 – 280/300°C
Similar Phases: DB-1701ms, HP-1701, VF-1701ms, CP-Sil 19 CB, CP-Sil 19 CB-ms, OV-1701, Rtx-1701, ZB-1701, SPB-1701, Equity-1701, BP-10, OPTIMA 1701, 007-1701, AT-1701
DB-35ms GC Columns
- Ideal for confirmational analyses
- Equivalent to (35%-phenyl)-methylpolysiloxane
- Mid Polarity
- Close equivalent to USP Phase G42
- Identical selectivity to DB-35
- Very low bleed characteristics, ideal for GC/MS
- Exact replacement of HP-35ms
- Bonded, cross-linked and solvent rinsable
- Excellent inertness for active compounds
- Temperature Limits: 50 – 340/360°C
Similar Phases: DB-35, HP-35, VF-35ms, OV-35, Rtx-35, Rtx-35ms, Rxi35Sil MS, ZB-35, ZB-35ht, SPB-35, BPX35, BPX608, OPTIMA 35 MS, 007-35, 007-35MS, AT-35, AT-35ms, MDN-35, Sup-Herb
DB-624 GC Columns
- Recommended for EPA methods 502.2 and 8021, as well as for fast GC/MS analysis of volatiles
- (6%-cyanopropyl-phenyl)-methylpolysiloxane
- Mid Polarity
- Equivalent to USP Phase G43
- Exact replacement of HP-624
- Bonded, cross-linked and solvent rinsable
- No cryogenics needed for US EPA Method 502.2
- Excellent for US EPA Methods 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240, 8260 and USP 467
- Excellent inertness for active compounds
- Temperature Limits: -20 – 280°C
Similar Phases: DB-1301, VF-624ms, VF-1301ms, CP-1301, CP-Select 624 CB, OV-624, OV-1301, Rtx-624, Rxi-624Sil MS, Rtx-1301, Rxi-1301Sil MS, ZB-624, ZB-624plus, SPB-624, BP624, BPX-Volatiles, OPTIMA 624, OPTIMA 1301, 007-624, 007-1301, 007-502, 007-608, AT-624, PE-624
DB-225ms GC Columns
- Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs)
- Equivalent to (50%-cyanopropylphenyl)-methylpolysiloxane
- Mid-High Polarity
- Close equivalent to USP Phase G7
- Very low bleed characteristics, ideal for GC/MS
- Bonded, cross-linked and solvent rinsable
- Temperature Limits: 40 – 240°C
Similar Phases: DB-225, HP-225, CP-Sil 43 CB, OV-255, Rtx-225, SPB-225, BP225, OPTIMA 225, 007-225, AT-225, SP-2330
DB-FFAP GC Columns
- Designed for the analysis of volatile fatty acids and phenols
- Nitroterephthalic acid modified polyethylene glycol
- High Polarity
- Close equivalent to USP Phase G35
- Exact replacement of OV-351
- Bonded, cross-linked and solvent rinsable (not recommended to use water or methanol to rinse)
- Temperature Limits: 40 – 250°C
Similar Phases: HP-FFAP, CP-FFAP CB, CP-Wax 58 FFAP CB, VF-DA, OV-351, Stabilwax-DA, ZB-FFAP, BP21, OPTIMA FFAP, OPTIMA FFAP Plus, PE-FFAP, Nukol, PERMABOND FFAP
Agilent J&W GC columns are tested against the strictest industry QC specifications for column bleed, sensitivity, and efficiency to give you utmost confidence in qualitative and quantitative results.
For QC test conditions, including the test probe mixture and the resulting chromatogram, refer to the Agilent J&W GC Column Performance Summary, shipped with each GC column.