large image
Loading...

Agilent DB-ALC GC Columns

Agilent J&W DB-ALC1 and DB-ALC2 analytical columns enable two minute blood alcohol content analysis, reducing run time by one third compared to other blood alcohol analysis columns. Due to its unique polarity, DB-ALC2 also provides better resolution of key ethanol/acetone peaks than other available blood alcohol confirmation columns. These columns are suitable for both headspace analysis and direct injections.

Part Number Short Description Film Thickness Phase ID Length Type Material Price Qty
123-9134 DB-ALC1, 30m x 0.32mm x 1.8um 1.80 um DB-ALC1 0.32 mm 30 m 7 inch Fused Silica
£647.00
123-9134E DB-ALC1, 30m x 0.32mm x 1.8um, 5in Cage 1.80 um DB-ALC1 0.32 mm 30 m 5 inch Fused Silica
£725.00
125-9134 DB-ALC1, 30m x 0.53mm x 3um 3.00 um DB-ALC1 0.53 mm 30 m 7 inch Fused Silica
£717.00
125-9134E DB-ALC1, 30m x 0.53mm x 3um, 5in Cage 3.00 um DB-ALC1 0.53 mm 30 m 5 inch Fused Silica
£804.00
123-9234 DB-ALC2, 30m x 0.32mm x 1.2um 1.20 um DB-ALC2 0.32 mm 30 m 7 inch Fused Silica
£647.00
123-9234E DB-ALC2, 30m x 0.32mm x 1.2um, 5in Cage 1.20 um DB-ALC2 0.32 mm 30 m 5 inch Fused Silica
£725.00
125-9234 DB-ALC2, 30m x 0.53mm x 2um 2.00 um DB-ALC2 0.53 mm 30 m 7 inch Fused Silica
£717.00
  • Reliable blood alcohol analysis
  • Optimised primary and confirmation column pair for U.S. blood alcohol analysis
  • Faster GC run times
  • Improved resolution of key ethanol/acetone peaks
  • Bonded and cross-linked
  • DB-ALC1 and DB-ALC2 columns are regularly used in sets. Connect them together easily with an Agilent Ultra Inert, universal press fit Y-splitter (5190-6980), or an UltiMetal Plus deactivated CFT un-purged splitter (G3184-60065)
  • Tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency
  • Performance Summary shipped with each column

Similar Phases: Rtx-BAC1, Rtx-BAC2, ZB-BAC-1, ZB-BAC-2


A 7 inch cage is the most common GC column format, compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems, and all non-Agilent GC systems with a similarly sized oven. The 5 inch cage format is designed for smaller GC ovens e.g. for the Agilent GC 6850.


DB-ALC Intuvo GC Columns with Smart Key are also available, which are specifically designed for use with the Intuvo 9000 GC instrument.

DB-ALC1 & DB-ALC2 Temperature Specifications

ID 0.32 mm 0.53 mm
Length 30 m 30 m
Film Thickness 1.80 µm (DB-ALC1)
1.20 µm (DB-ALC2)
3.00 µm (DB-ALC1)
2.00 µm (DB-ALC2)
Temperature Limits 20 – 260/280°C 20 – 260/280°C 
Agilent GC Column Brochure (11.67 MB)

Full range of Agilent Technologies GC columns and applications

© 2024 Element Materials Technology