large image
Loading...

Agilent DB-VRX GC Columns

Agilent J&W DB-VRX GC columns feature unique selectivity, engineered for optimum resolution of volatiles. These low polarity columns deliver excellent peak shapes and are fully compliant with U.S. EPA methods 502.2, 524.2, and 8260. They are bonded and cross-linked, and require no subambient cooling to resolve the six 'gases'. DB-VRX features an operating temperature range of –20 to 260°C.

Part Number Short Description Film Thickness Phase USP ID Length Type Material Price Qty
121-1544E DB-VRX, 40m x 0.18mm x 1um, 5inch Cage 1.00 um DB-VRX G53 0.18 mm 40 m 5 inch Fused Silica
£1,062.00
122-1564E DB-VRX, 60m x 0.25mm x 1.4um, 5inch Cage 1.40 um DB-VRX G53 0.25 mm 60 m 5 inch Fused Silica
£1,260.00
121-1524 DB-VRX, 20m x 0.18mm x 1um 1.00 um DB-VRX G53 0.18 mm 20 m 7 inch Fused Silica
£531.00
122-1534 DB-VRX, 30m x 0.25mm x 1.4um 1.40 um DB-VRX G53 0.25 mm 30 m 7 inch Fused Silica
£662.00
123-1534 DB-VRX, 30m x 0.32mm x 1.8um 1.80 um DB-VRX G53 0.32 mm 30 m 7 inch Fused Silica
£737.00
124-1534 DB-VRX, 30m x 0.45mm x 2.55um 2.55 um DB-VRX G53 0.45 mm 30 m 7 inch Fused Silica
£860.00
121-1544 DB-VRX, 40m x 0.18mm x 1um 1.00 um DB-VRX G53 0.18 mm 40 m 7 inch Fused Silica
£947.00
122-1564 DB-VRX, 60m x 0.25mm x 1.4um 1.40 um DB-VRX G53 0.25 mm 60 m 7 inch Fused Silica
£1,123.00
123-1564 DB-VRX, 60m x 0.32mm x 1.8um 1.80 um DB-VRX G53 0.32 mm 60 m 7 inch Fused Silica
£1,227.00
124-1574 DB-VRX, 75m x 0.45mm x 2.55um 2.55 um DB-VRX G53 0.45 mm 75 m 7 inch Fused Silica
£1,480.00
  • Low polarity
  • Unique selectivity engineered for optimum resolution of volatiles analysis: U.S. EPA Methods 502.2, 524.2 and 8260
  • 0.45mm ID columns provide more plates per meter compared to 0.53mm ID columns for the fewest co-elutions for GC method (an industry first)*
  • No subambient cooling required to resolve the six "gases"
  • Fast run time:
    < 30 minutes for optimum sample throughput
    < 8 minutes with 0.18mm ID
  • Excellent peak shape
  • Bonded and cross-linked
  • Solvent rinsable
  • Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
  • For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column

Similar Phases: VOCOL, NON-PAKD, Rtx-Volatiles, PE-Volatiles, 007-624, Rtx-VRX, Rtx-VGC

*Two co-elutions: 1) m- and p-xylene, for which U.S. EPA does not require separation, and 2) 1,1,2,2-tetrachloroethane and o-xylene which are separated by detectors PID and ELCD, respectively. Note to GC/MS analysts: These co-eluting compounds have different primary characteristic ions of 83 and 106, respectively.

DB-VRX Temperature Specifications

ID (mm) 0.18 - 0.32 mm 0.45 mm
Length (m) 20 - 60 m 30 - 75 m
Film (µm) 1.00 - 1.80 µm 2.55 µm
Temperature Limits (°C) -10 - 260 °C -10 - 260 °C 
Agilent GC Column Brochure (11.67 MB)

Full range of Agilent Technologies GC columns and applications

© 2024 Element Materials Technology