large image
Loading...

Avantor® ACE® NH2 HPLC Columns

Avantor® ACE® NH2 HPLC columns have proprietary bonding technology to provide high robustness with excellent column lifetimes. It is a versatile amino phase that can be used in reversed phase, normal phase, weak anion-exchange and HILIC modes. It is ideally suited for the separation of sugars.

Avantor® ACE® Excel® NH2 columns, with increased pressure rating of 1,000 bar, are available for UHPLC applications in 1.7, 3 and 5 μm particle sizes.

Part Number Short Description Phase Type Phase USP Particle Size ID Length Pore Size Type Price Qty
ACE-1114-0102GD ACE 3 NH2 Guards for 2.1mm ID Columns, 5pk Amino ACE NH2 L8 3 um 2.1 mm 100 A Guard
£276.57
ACE-1114-0103GD ACE 3 NH2 Guards for 3.0 - 4.6mm ID Columns, 5pk Amino ACE NH2 L8 3 um 3.0 - 4.6 mm 100 A Guard
£251.43
ACE-1214-2504 ACE 5 NH2 250 x 4mm Amino ACE NH2 L8 5 um 4.0 mm 250 mm 100 A Column
£886.86
ACE-1214-0103GD ACE 5 NH2 Guards for 3.0 - 4.6mm ID Columns, 5pk Amino ACE NH2 L8 5 um 3.0 - 4.6 mm 100 A Guard
£251.43
EXL-1714-1002U ACE Excel 1.7 NH2 100 x 2.1mm Amino ACE Excel NH2 L8 1.7 um 2.1 mm 100 mm 100 A Column
£906.29
EXL-1714-0502U ACE Excel 1.7 NH2 50 x 2.1mm Amino ACE Excel NH2 L8 1.7 um 2.1 mm 50 mm 100 A Column
£906.29
EXL-1114-1002U ACE Excel 3 NH2 100 x 2.1mm Amino ACE Excel NH2 L8 3 um 2.1 mm 100 mm 100 A Column
£856.00
EXL-1114-1502U ACE Excel 3 NH2 150 x 2.1mm Amino ACE Excel NH2 L8 3 um 2.1 mm 150 mm 100 A Column
£916.57
EXL-1114-1503U ACE Excel 3 NH2 150 x 3mm Amino ACE Excel NH2 L8 3 um 3.0 mm 150 mm 100 A Column
£916.57
EXL-1114-1546U ACE Excel 3 NH2 150 x 4.6mm Amino ACE Excel NH2 L8 3 um 4.6 mm 150 mm 100 A Column
£916.57
EXL-1114-2546U ACE Excel 3 NH2 250 x 4.6mm Amino ACE Excel NH2 L8 3 um 4.6 mm 250 mm 100 A Column
£1,041.14
EXL-1114-0502U ACE Excel 3 NH2 50 x 2.1mm Amino ACE Excel NH2 L8 3 um 2.1 mm 50 mm 100 A Column
£765.71
EXL-1114-0546U ACE Excel 3 NH2 50 x 4.6mm Amino ACE Excel NH2 L8 3 um 4.6 mm 50 mm 100 A Column
£765.71
EXL-1214-1246U ACE Excel 5 NH2 125 x 4.6mm Amino ACE Excel NH2 L8 5 um 4.6 mm 125 mm 100 A Column
£848.00
EXL-1214-1546U ACE Excel 5 NH2 150 x 4.6mm Amino ACE Excel NH2 L8 5 um 4.6 mm 150 mm 100 A Column
£874.29
EXL-1214-2546U ACE Excel 5 NH2 250 x 4.6mm Amino ACE Excel NH2 L8 5 um 4.6 mm 250 mm 100 A Column
£916.57
EXL-1214-0546U ACE Excel 5 NH2 50 x 4.6mm Amino ACE Excel NH2 L8 5 um 4.6 mm 50 mm 100 A Column
£801.14
  • Versatile phase usable in reversed-phase, normal-phase, weak anion exchange and HILIC modes
  • Ionisable positive surface charge depending on the mobile phase pH
  • Ideal phase for the analysis of sugars
  • Shipped in reversed phase solvents as specified on accompanying test chromatogram
  • USP classification of L8
  • Part numbers beginning with ACE have HPLC hardware format with 275 bar / 4,000 psi pressure limit
  • Part numbers beginning with EXL have HPLC/UHPLC hardware format with 1,000 bar / 15,000 psi pressure limit
  • ACE guard cartridges for analytical columns require stand-alone guard cartridge holder H0001 and column coupler C0001
  • ACE UHPLC guard cartridges require holder H0011
  Avantor® ACE® NH2
Bonded Group Proprietary aminopropyl
Particle Type Fully Porous
Particle Size 1.7 µm, 3 µm, 5 µm
Pore Size 100 Å
Surface Area 300 m2/g
Endcapped Proprietary
Carbon Load 3.5%
pH Range 2 - 7
100% Aqueous Compatible Yes
Pressure Limit ACE hardware - 275 bar
EXL hardware - 1000 bar
Hardware Stainless Steel
USP Designation L8
Avantor ACE HPLC and UHPLC Columns Catalogue (9.26 MB)
Product catalogue containing the full range of Avantor ACE columns
Avantor ACE Phase Guide (152.80 kB)
Specifications of the Avantor ACE columns