large image
Loading...

Agilent Organic GPC Columns for Light Scattering Detection

Agilent offers organic GPC columns for polymer analysis specifically designed for use with light scattering detectors. They are pre-equilibrated allowing for immediate installation and operation on the same day. With low noise levels and excellent signal-to-noise ratios, these columns reach steady state mode more rapidly than conventional columns, while maintaining the same robust functionality and linear calibration as traditional GPC columns.

The organic GPC columns for light scattering detectors includes the following ranges:

  • GRAM Lux for the separation of polar macromolecules with medium polarity organic eluents
  • PFG Lux to analyse crystalline polymers with fluorinated organic eluents
  • SDV Lux for the analysis of non-polar polymers using non-polar organic eluents
  • PLgel MIXED for the separation of non-polar polymers using non-polar organic eluents
Part Number Short Description Phase Particle Size ID Length Pore Size Type Price Qty
PL1110-6100LS PLgel Mixed-B LS Column, 10um, 300 x 7.5mm Plgel Mixed-B 10 um 7.5 mm 300 mm Mixed Column
£1,601.00
PL1110-6200LS PLgel Mixed-A LS Column, 20um, 300 x 7.5mm Plgel Mixed-A 20 um 7.5 mm 300 mm Mixed Column
£1,664.00
AMA080510LS GRAM Lux Guard Column, 10um, 8 x 50mm GRAM Lux 10 um 8.0 mm 50 mm Guard
£489.00
AMA0830101E2LS GRAM Lux Column, 100A, 10um, 8 x 300mm GRAM Lux 10 um 8.0 mm 300 mm 100 A Column
£1,541.00
AMA0830101E3LS GRAM Lux Column, 1000A, 10um, 8 x 300mm GRAM Lux 10 um 8.0 mm 300 mm 1000 A Column
£1,541.00
AMA0830101E4LS GRAM Lux Column, 10,000A, 10um, 8 x 300mm GRAM Lux 10 um 8.0 mm 300 mm 10,000 A Column
£1,541.00
AMA0830103E1LS GRAM Lux Column, 30A, 10um, 8 x 300mm GRAM Lux 10 um 8.0 mm 300 mm 30 A Column
£1,541.00
AMA0830103E3LS GRAM Lux Column, 3000A, 10um, 8 x 300mm GRAM Lux 10 um 8.0 mm 300 mm 3000 A Column
£1,541.00
PFA080505LS PFG Lux Guard Column, 5um, 8 x 50mm PFG Lux 5 um 8.0 mm 50 mm Guard
£489.00
PFA080507LS PFG Lux Guard Column, 7um, 8 x 50mm PFG Lux 7 um 8.0 mm 50 mm Guard
£489.00
PFA0830051E2LS PFG Lux Column, 100A, 5um, 8 x 300mm PFG Lux 5 um 8.0 mm 300 mm 100 A Column
£1,723.00
PFA083007LIMLS PFG Lux Linear M Column, 7um, 8 x 300mm PFG Lux 7 um 8.0 mm 300 mm Mixed Column
£1,793.00
PFA083007LXLLS PFG Lux Linear XL Column, 7um, 8 x 300mm PFG Lux 7 um 8.0 mm 300 mm Mixed Column
£1,793.00
SDA080503LS SDV Lux Guard Column, 3um, 8 x 50mm SDV Lux 3 um 8.0 mm 50 mm Guard
£489.00
SDA080505LS SDV Lux Guard Column, 5um, 8 x 50mm SDV Lux 5 um 8.0 mm 50 mm Guard
£489.00
SDA080510LS SDV Lux Guard Column, 10um, 8 x 50mm SDV Lux 10 um 8.0 mm 50 mm Guard
£489.00
SDA0830031E3LS SDV Lux Column, 1000A, 3um, 8 x 300mm SDV Lux 3 um 8.0 mm 300 mm 1000 A Column
£1,824.00
SDA0830031E4LS SDV Lux Column, 10,000A, 3um, 8 x 300mm SDV Lux 3 um 8.0 mm 300 mm 10,000 A Column
£1,824.00
SDA0830051E3LS SDV Lux Column, 1000A, 5um, 8 x 300mm SDV Lux 5 um 8.0 mm 300 mm 1000 A Column
£1,618.00
SDA0830051E5LS SDV Lux Column, 100,000A, 5um, 8 x 300mm SDV Lux 5 um 8.0 mm 300 mm 100,000 A Column
£1,618.00
SDA0830051E6LS SDV Lux Column, 1,000,000A, 5um, 8 x 300mm SDV Lux 5 um 8.0 mm 300 mm 1,000,000 A Column
£1,618.00
SDA0830101E3LS SDV Lux Column, 1000A, 10um, 8 x 300mm SDV Lux 10 um 8.0 mm 300 mm 1000 A Column
£1,428.00
SDA0830101E5LS SDV Lux Column, 100,000 A, 10um, 8 x 300mm SDV Lux 10 um 8.0 mm 300 mm 100,000 A Column
£1,428.00
SDA0830101E7LS SDV Lux Column, 10,000,000A, 10um, 8 x 300mm SDV Lux 10 um 8.0 mm 300 mm 10,000,000 A Column
£1,428.00
  • Organic GPC columns with good signal-to-noise ratio out of the box
  • Eliminates baseline noise when used with light scattering detectors
  • Reaches steady state mode faster than traditional GPC columns
  • Columns are pre-equilibrated so can be installed and run same day
  • Same robust operation and linear calibration as traditional GRAM, PFG, SDV, and PLgel columns
  • Guard columns protect and extend the lifetime of analytical columns
Agilent GPC/SEC Columns and Consumables Brochure (1.08 MB)
Uncompromising analysis of polymers and macromolecules with the expanded portfolio of Agilent GPC/SEC columns and standards
Agilent GPC/SEC eBook (2.16 MB)
What you should know when you need to analyze polymers, biopolymers, and proteins
Agilent GRAM GPC/SEC Column User Manual (1.70 MB)
Instructions and best practices for using the Agilent GRAM GPC/SEC columns
Agilent PFG GPC/SEC Column User Manual (1.69 MB)
Instructions and best practices for using the Agilent PFC GPC/SEC columns
Agilent SDV Column User Manual (1.75 MB)
Instructions and best practices for using the Agilent SDV GPC/SEC columns
© 2024 Element Materials Technology