large image
Loading...

YMC-Triart C8

YMC-Triart C8 Analytical HPLC Columns

The versatility of YMC-Triart C8 makes it an optimum alternative for analysing acidic, neutral, basic and chelating compounds or metabolites. YMC-Triart C8 provides a less hydrophobic stationary phase offering a different selectivity and reduced retention times compared to YMC-Triart C18.

Part Number Short Description Phase Type Phase USP Particle Size ID Length Pore Size Type Price Qty
TO12S03-10Q1PTH YMC-Triart C8 Column, 12nm, 3um, 100 x 2.1mm, PTH Hardware C8 YMC-Triart C8 L7 3 um 2.1 mm 100 mm 120 A Column
£590.06
TO12S03-1003PTH YMC-Triart C8 Column, 12nm, 3um, 100 x 3mm, PTH Hardware C8 YMC-Triart C8 L7 3 um 3.0 mm 100 mm 120 A Column
£629.74
TO12S03-1046PTH YMC-Triart C8 Column, 12nm, 3um, 100 x 4.6mm, PTH Hardware C8 YMC-Triart C8 L7 3 um 4.6 mm 100 mm 120 A Column
£657.40
TO12S03-15Q1PTH YMC-Triart C8 Column, 12nm, 3um, 150 x 2.1mm, PTH Hardware C8 YMC-Triart C8 L7 3 um 2.1 mm 150 mm 120 A Column
£695.10
TO12S03-1503PTH YMC-Triart C8 Column, 12nm, 3um, 150 x 3mm, PTH Hardware C8 YMC-Triart C8 L7 3 um 3.0 mm 150 mm 120 A Column
£709.84
TO12S03-1546PTH YMC-Triart C8 Column, 12nm, 3um, 150 x 4.6mm, PTH Hardware C8 YMC-Triart C8 L7 3 um 4.6 mm 150 mm 120 A Column
£762.43
TO12S03-2546PTH YMC-Triart C8 Column, 12nm, 3um, 250 x 4.6mm, PTH Hardware C8 YMC-Triart C8 L7 3 um 4.6 mm 250 mm 120 A Column
£844.51
TO12S03-H3Q1PTH YMC-Triart C8 Column, 12nm, 3um, 33 x 2.1mm, PTH Hardware C8 YMC-Triart C8 L7 3 um 2.1 mm 33 mm 120 A Column
£590.06
TO12S03-H346PTH YMC-Triart C8 Column, 12nm, 3um, 33 x 4.6mm, PTH Hardware C8 YMC-Triart C8 L7 3 um 4.6 mm 33 mm 120 A Column
£548.57
TO12S03-05Q1PTH YMC-Triart C8 Column, 12nm, 3um, 50 x 2.1mm, PTH Hardware C8 YMC-Triart C8 L7 3 um 2.1 mm 50 mm 120 A Column
£590.06
TO12S03-0503PTH YMC-Triart C8 Column, 12nm, 3um, 50 x 3mm, PTH Hardware C8 YMC-Triart C8 L7 3 um 3.0 mm 50 mm 120 A Column
£548.57
TO12S03-0546PTH YMC-Triart C8 Column, 12nm, 3um, 50 x 4.6mm, PTH Hardware C8 YMC-Triart C8 L7 3 um 4.6 mm 50 mm 120 A Column
£562.41
TO12S03-L5Q1PTH YMC-Triart C8 Column, 12nm, 3um, 75 x 2.1mm, PTH Hardware C8 YMC-Triart C8 L7 3 um 2.1 mm 75 mm 120 A Column
£590.06
TO12S03-L503PTH YMC-Triart C8 Column, 12nm, 3um, 75 x 3mm, PTH Hardware C8 YMC-Triart C8 L7 3 um 3.0 mm 75 mm 120 A Column
£548.57
TO12S03-L546PTH YMC-Triart C8 Column, 12nm, 3um, 75 x 4.6mm, PTH Hardware C8 YMC-Triart C8 L7 3 um 4.6 mm 75 mm 120 A Column
£562.41
TO12S05-10Q1PTH YMC-Triart C8 Column, 12nm, 5um, 100 x 2.1mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 2.1 mm 100 mm 120 A Column
£657.40
TO12S05-1003PTH YMC-Triart C8 Column, 12nm, 5um, 100 x 3mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 3.0 mm 100 mm 120 A Column
£615.91
TO12S05-1046PTH YMC-Triart C8 Column, 12nm, 5um, 100 x 4.6mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 4.6 mm 100 mm 120 A Column
£635.22
TO12S05-15Q1PTH YMC-Triart C8 Column, 12nm, 5um, 150 x 2.1mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 2.1 mm 150 mm 120 A Column
£682.18
TO12S05-1503PTH YMC-Triart C8 Column, 12nm, 5um, 150 x 3mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 3.0 mm 150 mm 120 A Column
£657.40
TO12S05-1546PTH YMC-Triart C8 Column, 12nm, 5um, 150 x 4.6mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 4.6 mm 150 mm 120 A Column
£695.10
TO12S05-1504PTH YMC-Triart C8 Column, 12nm, 5um, 150 x 4mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 4.0 mm 150 mm 120 A Column
£695.10
TO12S05-02Q1PTH YMC-Triart C8 Column, 12nm, 5um, 20 x 2.1mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 2.1 mm 20 mm 120 A Column
£590.06
TO12S05-2503PTH YMC-Triart C8 Column, 12nm, 5um, 250 x 3mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 3.0 mm 250 mm 120 A Column
£736.60
TO12S05-2546PTH YMC-Triart C8 Column, 12nm, 5um, 250 x 4.6mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 4.6 mm 250 mm 120 A Column
£803.94
TO12S05-2504PTH YMC-Triart C8 Column, 12nm, 5um, 250 x 4mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 4.0 mm 250 mm 120 A Column
£803.94
TO12S05-H3Q1PTH YMC-Triart C8 Column, 12nm, 5um, 33 x 2.1mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 2.1 mm 33 mm 120 A Column
£590.06
TO12S05-H346PTH YMC-Triart C8 Column, 12nm, 5um, 33 x 4.6mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 4.6 mm 33 mm 120 A Column
£548.57
TO12S05-05Q1PTH YMC-Triart C8 Column, 12nm, 5um, 50 x 2.1mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 2.1 mm 50 mm 120 A Column
£575.32
TO12S05-0503PTH YMC-Triart C8 Column, 12nm, 5um, 50 x 3mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 3.0 mm 50 mm 120 A Column
£548.57
TO12S05-0546PTH YMC-Triart C8 Column, 12nm, 5um, 50 x 4.6mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 4.6 mm 50 mm 120 A Column
£562.41
TO12S05-L5Q1PTH YMC-Triart C8 Column, 12nm, 5um, 75 x 2.1mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 2.1 mm 75 mm 120 A Column
£575.32
TO12S05-L503PTH YMC-Triart C8 Column, 12nm, 5um, 75 x 3mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 3.0 mm 75 mm 120 A Column
£548.57
TO12S05-L546PTH YMC-Triart C8 Column, 12nm, 5um, 75 x 4.6mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 4.6 mm 75 mm 120 A Column
£562.41
TO12SP9-10H0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 1.9um, 100 x 300um C8 YMC-Triart C8 L7 1.9 um 0.3 mm 100 mm 120 A 1/16in Column
£892.40
TO12SP9-10J0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 1.9um, 100 x 500um C8 YMC-Triart C8 L7 1.9 um 0.5 mm 100 mm 120 A 1/16in Column
£892.40
TO12SP9-15H0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 1.9um, 150 x 300um C8 YMC-Triart C8 L7 1.9 um 0.3 mm 150 mm 120 A 1/16in Column
£892.40
TO12SP9-15J0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 1.9um, 150 x 500um C8 YMC-Triart C8 L7 1.9 um 0.5 mm 150 mm 120 A 1/16in Column
£892.40
TO12SP9-05H0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 1.9um, 50 x 300um C8 YMC-Triart C8 L7 1.9 um 0.3 mm 50 mm 120 A 1/16in Column
£892.40
TO12SP9-05J0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 1.9um, 50 x 500um C8 YMC-Triart C8 L7 1.9 um 0.5 mm 50 mm 120 A 1/16in Column
£892.40
TO12SP9-L5H0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 1.9um, 75 x 300um C8 YMC-Triart C8 L7 1.9 um 0.3 mm 75 mm 120 A 1/16in Column
£892.40
TO12SP9-L5J0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 1.9um, 75 x 500um C8 YMC-Triart C8 L7 1.9 um 0.5 mm 75 mm 120 A 1/16in Column
£892.40
TO12S03-10F0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 3um, 100 x 100um C8 YMC-Triart C8 L7 3 um 0.1 mm 100 mm 120 A 1/16in Column
£892.40
TO12S03-10H0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 3um, 100 x 300um C8 YMC-Triart C8 L7 3 um 0.3 mm 100 mm 120 A 1/16in Column
£892.40
TO12S03-10J0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 3um, 100 x 500um C8 YMC-Triart C8 L7 3 um 0.5 mm 100 mm 120 A 1/16in Column
£892.40
TO12S03-10E8AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 3um, 100 x 75um C8 YMC-Triart C8 L7 3 um 0.075 mm 100 mm 120 A 1/16in Column
£892.40
TO12S03-15F0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 3um, 150 x 100um C8 YMC-Triart C8 L7 3 um 0.1 mm 150 mm 120 A 1/16in Column
£892.40
TO12S03-15H0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 3um, 150 x 300um C8 YMC-Triart C8 L7 3 um 0.3 mm 150 mm 120 A 1/16in Column
£892.40
TO12S03-15J0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 3um, 150 x 500um C8 YMC-Triart C8 L7 3 um 0.5 mm 150 mm 120 A 1/16in Column
£892.40
TO12S03-15E8AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 3um, 150 x 75um C8 YMC-Triart C8 L7 3 um 0.075 mm 150 mm 120 A 1/16in Column
£892.40
TO12S03-05H0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 3um, 50 x 300um C8 YMC-Triart C8 L7 3 um 0.3 mm 50 mm 120 A 1/16in Column
£892.40
TO12S03-05J0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 3um, 50 x 500um C8 YMC-Triart C8 L7 3 um 0.5 mm 50 mm 120 A 1/16in Column
£892.40
TO12S03-L5H0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 3um, 75 x 300um C8 YMC-Triart C8 L7 3 um 0.3 mm 75 mm 120 A 1/16in Column
£892.40
TO12S03-L5J0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 3um, 75 x 500um C8 YMC-Triart C8 L7 3 um 0.5 mm 75 mm 120 A 1/16in Column
£892.40
TO12S05-10F0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 5um, 100 x 100um C8 YMC-Triart C8 L7 5 um 0.1 mm 100 mm 120 A 1/16in Column
£892.40
TO12S05-10H0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 5um, 100 x 300um C8 YMC-Triart C8 L7 5 um 0.3 mm 100 mm 120 A 1/16in Column
£892.40
TO12S05-10J0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 5um, 100 x 500um C8 YMC-Triart C8 L7 5 um 0.5 mm 100 mm 120 A 1/16in Column
£892.40
TO12S05-10E8AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 5um, 100 x 75um C8 YMC-Triart C8 L7 5 um 0.075 mm 100 mm 120 A 1/16in Column
£892.40
TO12S05-15F0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 5um, 150 x 100um C8 YMC-Triart C8 L7 5 um 0.1 mm 150 mm 120 A 1/16in Column
£892.40
TO12S05-15H0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 5um, 150 x 300um C8 YMC-Triart C8 L7 5 um 0.3 mm 150 mm 120 A 1/16in Column
£892.40
TO12S05-15J0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 5um, 150 x 500um C8 YMC-Triart C8 L7 5 um 0.5 mm 150 mm 120 A 1/16in Column
£892.40
TO12S05-15E8AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 5um, 150 x 75um C8 YMC-Triart C8 L7 5 um 0.075 mm 150 mm 120 A 1/16in Column
£892.40
TO12S05-05H0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 5um, 50 x 300um C8 YMC-Triart C8 L7 5 um 0.3 mm 50 mm 120 A 1/16in Column
£892.40
TO12S05-05J0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 5um, 50 x 500um C8 YMC-Triart C8 L7 5 um 0.5 mm 50 mm 120 A 1/16in Column
£892.40
TO12S05-L5H0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 5um, 75 x 300um C8 YMC-Triart C8 L7 5 um 0.3 mm 75 mm 120 A 1/16in Column
£892.40
TO12S05-L5J0AU YMC-Triart C8 Capillary Column 1/16in, 12nm, 5um, 75 x 500um C8 YMC-Triart C8 L7 5 um 0.5 mm 75 mm 120 A 1/16in Column
£892.40
TO12SP9-10H0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 1.9um, 100 x 300um C8 YMC-Triart C8 L7 1.9 um 0.3 mm 100 mm 120 A 1/32in Column
£892.40
TO12SP9-10J0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 1.9um, 100 x 500um C8 YMC-Triart C8 L7 1.9 um 0.5 mm 100 mm 120 A 1/32in Column
£892.40
TO12SP9-15H0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 1.9um, 150 x 300um C8 YMC-Triart C8 L7 1.9 um 0.3 mm 150 mm 120 A 1/32in Column
£892.40
TO12SP9-15J0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 1.9um, 150 x 500um C8 YMC-Triart C8 L7 1.9 um 0.5 mm 150 mm 120 A 1/32in Column
£892.40
TO12SP9-05H0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 1.9um, 50 x 300um C8 YMC-Triart C8 L7 1.9 um 0.3 mm 50 mm 120 A 1/32in Column
£892.40
TO12SP9-05J0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 1.9um, 50 x 500um C8 YMC-Triart C8 L7 1.9 um 0.5 mm 50 mm 120 A 1/32in Column
£892.40
TO12SP9-L5H0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 1.9um, 75 x 300um C8 YMC-Triart C8 L7 1.9 um 0.3 mm 75 mm 120 A 1/32in Column
£892.40
TO12SP9-L5J0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 1.9um, 75 x 500um C8 YMC-Triart C8 L7 1.9 um 0.5 mm 75 mm 120 A 1/32in Column
£892.40
TO12S03-10H0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 3um, 100 x 300um C8 YMC-Triart C8 L7 3 um 0.3 mm 100 mm 120 A 1/32in Column
£892.40
TO12S03-10J0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 3um, 100 x 500um C8 YMC-Triart C8 L7 3 um 0.5 mm 100 mm 120 A 1/32in Column
£892.40
TO12S03-15H0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 3um, 150 x 300um C8 YMC-Triart C8 L7 3 um 0.3 mm 150 mm 120 A 1/32in Column
£892.40
TO12S03-15J0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 3um, 150 x 500um C8 YMC-Triart C8 L7 3 um 0.5 mm 150 mm 120 A 1/32in Column
£892.40
TO12S03-05H0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 3um, 50 x 300um C8 YMC-Triart C8 L7 3 um 0.3 mm 50 mm 120 A 1/32in Column
£892.40
TO12S03-05J0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 3um, 50 x 500um C8 YMC-Triart C8 L7 3 um 0.5 mm 50 mm 120 A 1/32in Column
£892.40
TO12S03-L5H0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 3um, 75 x 300um C8 YMC-Triart C8 L7 3 um 0.3 mm 75 mm 120 A 1/32in Column
£892.40
TO12S03-L5J0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 3um, 75 x 500um C8 YMC-Triart C8 L7 3 um 0.5 mm 75 mm 120 A 1/32in Column
£892.40
TO12S05-10H0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 5um, 100 x 300um C8 YMC-Triart C8 L7 5 um 0.3 mm 100 mm 120 A 1/32in Column
£892.40
TO12S05-10J0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 5um, 100 x 500um C8 YMC-Triart C8 L7 5 um 0.5 mm 100 mm 120 A 1/32in Column
£892.40
TO12S05-15H0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 5um, 150 x 300um C8 YMC-Triart C8 L7 5 um 0.3 mm 150 mm 120 A 1/32in Column
£892.40
TO12S05-15J0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 5um, 150 x 500um C8 YMC-Triart C8 L7 5 um 0.5 mm 150 mm 120 A 1/32in Column
£892.40
TO12S05-05H0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 5um, 50 x 300um C8 YMC-Triart C8 L7 5 um 0.3 mm 50 mm 120 A 1/32in Column
£892.40
TO12S05-05J0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 5um, 50 x 500um C8 YMC-Triart C8 L7 5 um 0.5 mm 50 mm 120 A 1/32in Column
£892.40
TO12S05-L5H0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 5um, 75 x 300um C8 YMC-Triart C8 L7 5 um 0.3 mm 75 mm 120 A 1/32in Column
£892.40
TO12S05-L5J0RU YMC-Triart C8 Capillary Column 1/32in, 12nm, 5um, 75 x 500um C8 YMC-Triart C8 L7 5 um 0.5 mm 75 mm 120 A 1/32in Column
£892.40
TO12SP9-E5H0AU YMC-Triart C8 Capillary Guard Column 1/16in, 12nm, 1.9um, 5 x 300um, 3pk C8 YMC-Triart C8 L7 1.9 um 0.3 mm 5 mm 120 A 1/16in Guard
£463.75
TO12SP9-E5J0AU YMC-Triart C8 Capillary Guard Column 1/16in, 12nm, 1.9um, 5 x 500um, 3pk C8 YMC-Triart C8 L7 1.9 um 0.5 mm 5 mm 120 A 1/16in Guard
£463.75
TO12S03-E5H0AU YMC-Triart C8 Capillary Guard Column 1/16in, 12nm, 3um, 5 x 300um, 3pk C8 YMC-Triart C8 L7 3 um 0.3 mm 5 mm 120 A 1/16in Guard
£463.75
TO12S03-E5J0AU YMC-Triart C8 Capillary Guard Column 1/16in, 12nm, 3um, 5 x 500um, 3pk C8 YMC-Triart C8 L7 3 um 0.5 mm 5 mm 120 A 1/16in Guard
£463.75
TO12S05-E5H0AU YMC-Triart C8 Capillary Guard Column 1/16in, 12nm, 5um, 5 x 300um, 3pk C8 YMC-Triart C8 L7 5 um 0.3 mm 5 mm 120 A 1/16in Guard
£463.75
TO12S05-E5J0AU YMC-Triart C8 Capillary Guard Column 1/16in, 12nm, 5um, 5 x 500um, 3pk C8 YMC-Triart C8 L7 5 um 0.5 mm 5 mm 120 A 1/16in Guard
£463.75
TO12SP9-E5H0RU YMC-Triart C8 Capillary Guard Column 1/32in, 12nm, 1.9um, 5 x 300um, 3pk C8 YMC-Triart C8 L7 1.9 um 0.3 mm 5 mm 120 A 1/32in Guard
£463.75
TO12SP9-E5J0RU YMC-Triart C8 Capillary Guard Column 1/32in, 12nm, 1.9um, 5 x 500um, 3pk C8 YMC-Triart C8 L7 1.9 um 0.5 mm 5 mm 120 A 1/32in Guard
£463.75
TO12S03-E5H0RU YMC-Triart C8 Capillary Guard Column 1/32in, 12nm, 3um, 5 x 300um, 3pk C8 YMC-Triart C8 L7 3 um 0.3 mm 5 mm 120 A 1/32in Guard
£463.75
TO12S03-E5J0RU YMC-Triart C8 Capillary Guard Column 1/32in, 12nm, 3um, 5 x 500um, 3pk C8 YMC-Triart C8 L7 3 um 0.5 mm 5 mm 120 A 1/32in Guard
£463.75
TO12S05-E5H0RU YMC-Triart C8 Capillary Guard Column 1/32in, 12nm, 5um, 5 x 300um, 3pk C8 YMC-Triart C8 L7 5 um 0.3 mm 5 mm 120 A 1/32in Guard
£463.75
TO12S05-E5J0RU YMC-Triart C8 Capillary Guard Column 1/32in, 12nm, 5um, 5 x 500um, 3pk C8 YMC-Triart C8 L7 5 um 0.5 mm 5 mm 120 A 1/32in Guard
£463.75
TO12S03-1002WT YMC-Triart C8 Column, 12nm, 3um, 100 x 2mm, WT Hardware C8 YMC-Triart C8 L7 3 um 2.0 mm 100 mm 120 A Column
£590.06
TO12S03-1003WT YMC-Triart C8 Column, 12nm, 3um, 100 x 3mm, WT Hardware C8 YMC-Triart C8 L7 3 um 3.0 mm 100 mm 120 A Column
£629.74
TO12S03-1046WT YMC-Triart C8 Column, 12nm, 3um, 100 x 4.6mm, WT Hardware C8 YMC-Triart C8 L7 3 um 4.6 mm 100 mm 120 A Column
£657.40
TO12S03-1502WT YMC-Triart C8 Column, 12nm, 3um, 150 x 2mm, WT Hardware C8 YMC-Triart C8 L7 3 um 2.0 mm 150 mm 120 A Column
£695.10
TO12S03-1503WT YMC-Triart C8 Column, 12nm, 3um, 150 x 3mm, WT Hardware C8 YMC-Triart C8 L7 3 um 3.0 mm 150 mm 120 A Column
£709.84
TO12S03-1546WT YMC-Triart C8 Column, 12nm, 3um, 150 x 4.6mm, WT Hardware C8 YMC-Triart C8 L7 3 um 4.6 mm 150 mm 120 A Column
£762.43
TO12S03-2502WT YMC-Triart C8 Column, 12nm, 3um, 250 x 2mm, WT Hardware C8 YMC-Triart C8 L7 3 um 2.0 mm 250 mm 120 A Column
£723.67
TO12S03-2546WT YMC-Triart C8 Column, 12nm, 3um, 250 x 4.6mm, WT Hardware C8 YMC-Triart C8 L7 3 um 4.6 mm 250 mm 120 A Column
£844.51
TO12S03-0302WT YMC-Triart C8 Column, 12nm, 3um, 30 x 2mm, WT Hardware C8 YMC-Triart C8 L7 3 um 2.0 mm 30 mm 120 A Column
£590.06
TO12S03-0346WT YMC-Triart C8 Column, 12nm, 3um, 30 x 4.6mm, WT Hardware C8 YMC-Triart C8 L7 3 um 4.6 mm 30 mm 120 A Column
£548.57
TO12S03-0501WT YMC-Triart C8 Column, 12nm, 3um, 50 x 1mm, WT Hardware C8 YMC-Triart C8 L7 3 um 1.0 mm 50 mm 120 A Column
£723.67
TO12S03-05Q1WT YMC-Triart C8 Column, 12nm, 3um, 50 x 2.1mm, WT Hardware C8 YMC-Triart C8 L7 3 um 2.1 mm 50 mm 120 A Column
£590.06
TO12S03-0502WT YMC-Triart C8 Column, 12nm, 3um, 50 x 2mm, WT Hardware C8 YMC-Triart C8 L7 3 um 2.0 mm 50 mm 120 A Column
£590.06
TO12S03-0503WT YMC-Triart C8 Column, 12nm, 3um, 50 x 3mm, WT Hardware C8 YMC-Triart C8 L7 3 um 3.0 mm 50 mm 120 A Column
£548.57
TO12S03-0546WT YMC-Triart C8 Column, 12nm, 3um, 50 x 4.6mm, WT Hardware C8 YMC-Triart C8 L7 3 um 4.6 mm 50 mm 120 A Column
£562.41
TO12S03-L502WT YMC-Triart C8 Column, 12nm, 3um, 75 x 2mm, WT Hardware C8 YMC-Triart C8 L7 3 um 2.0 mm 75 mm 120 A Column
£590.06
TO12S03-L503WT YMC-Triart C8 Column, 12nm, 3um, 75 x 3mm, WT Hardware C8 YMC-Triart C8 L7 3 um 3.0 mm 75 mm 120 A Column
£548.57
TO12S03-L546WT YMC-Triart C8 Column, 12nm, 3um, 75 x 4.6mm, WT Hardware C8 YMC-Triart C8 L7 3 um 4.6 mm 75 mm 120 A Column
£562.41
TO12S05-1002WT YMC-Triart C8 Column, 12nm, 5um, 100 x 2mm, WT Hardware C8 YMC-Triart C8 L7 5 um 2.0 mm 100 mm 120 A Column
£657.40
TO12S05-1003WT YMC-Triart C8 Column, 12nm, 5um, 100 x 3mm, WT Hardware C8 YMC-Triart C8 L7 5 um 3.0 mm 100 mm 120 A Column
£615.91
TO12S05-1046WT YMC-Triart C8 Column, 12nm, 5um, 100 x 4.6mm, WT Hardware C8 YMC-Triart C8 L7 5 um 4.6 mm 100 mm 120 A Column
£635.22
TO12S05-1502WT YMC-Triart C8 Column, 12nm, 5um, 150 x 2mm, WT Hardware C8 YMC-Triart C8 L7 5 um 2.0 mm 150 mm 120 A Column
£682.18
TO12S05-1503WT YMC-Triart C8 Column, 12nm, 5um, 150 x 3mm, WT Hardware C8 YMC-Triart C8 L7 5 um 3.0 mm 150 mm 120 A Column
£657.40
TO12S05-1546WT YMC-Triart C8 Column, 12nm, 5um, 150 x 4.6mm, WT Hardware C8 YMC-Triart C8 L7 5 um 4.6 mm 150 mm 120 A Column
£695.10
TO12S05-1504WT YMC-Triart C8 Column, 12nm, 5um, 150 x 4mm, WT Hardware C8 YMC-Triart C8 L7 5 um 4.0 mm 150 mm 120 A Column
£695.10
TO12S05-0202WT YMC-Triart C8 Column, 12nm, 5um, 20 x 2mm, WT Hardware C8 YMC-Triart C8 L7 5 um 2.0 mm 20 mm 120 A Column
£590.06
TO12S05-2502WT YMC-Triart C8 Column, 12nm, 5um, 250 x 2mm, WT Hardware C8 YMC-Triart C8 L7 5 um 2.0 mm 250 mm 120 A Column
£723.67
TO12S05-2503WT YMC-Triart C8 Column, 12nm, 5um, 250 x 3mm, WT Hardware C8 YMC-Triart C8 L7 5 um 3.0 mm 250 mm 120 A Column
£736.60
TO12S05-2546WT YMC-Triart C8 Column, 12nm, 5um, 250 x 4.6mm, WT Hardware C8 YMC-Triart C8 L7 5 um 4.6 mm 250 mm 120 A Column
£803.94
TO12S05-2504WT YMC-Triart C8 Column, 12nm, 5um, 250 x 4mm, WT Hardware C8 YMC-Triart C8 L7 5 um 4.0 mm 250 mm 120 A Column
£803.94
TO12S05-0346WT YMC-Triart C8 Column, 12nm, 5um, 30 x 4.6mm, WT Hardware C8 YMC-Triart C8 L7 5 um 4.6 mm 30 mm 120 A Column
£548.57
TO12S05-0502WT YMC-Triart C8 Column, 12nm, 5um, 50 x 2mm, WT Hardware C8 YMC-Triart C8 L7 5 um 2.0 mm 50 mm 120 A Column
£575.32
TO12S05-0503WT YMC-Triart C8 Column, 12nm, 5um, 50 x 3mm, WT Hardware C8 YMC-Triart C8 L7 5 um 3.0 mm 50 mm 120 A Column
£548.57
TO12S05-0546WT YMC-Triart C8 Column, 12nm, 5um, 50 x 4.6mm, WT Hardware C8 YMC-Triart C8 L7 5 um 4.6 mm 50 mm 120 A Column
£562.41
TO12S05-L502WT YMC-Triart C8 Column, 12nm, 5um, 75 x 2mm, WT Hardware C8 YMC-Triart C8 L7 5 um 2.0 mm 75 mm 120 A Column
£575.32
TO12S05-L503WT YMC-Triart C8 Column, 12nm, 5um, 75 x 3mm, WT Hardware C8 YMC-Triart C8 L7 5 um 3.0 mm 75 mm 120 A Column
£548.57
TO12S05-L546WT YMC-Triart C8 Column, 12nm, 5um, 75 x 4.6mm, WT Hardware C8 YMC-Triart C8 L7 5 um 4.6 mm 75 mm 120 A Column
£562.41
TO12S03-01Q1GC YMC-Triart C8 Guard Cartridge, 12nm, 3um, 10 x 2.1mm, 5pk C8 YMC-Triart C8 L7 3 um 2.1 mm 10 mm 120 A Guard
£451.74
TO12S03-0103GC YMC-Triart C8 Guard Cartridge, 12nm, 3um, 10 x 3mm, 5pk C8 YMC-Triart C8 L7 3 um 3.0 mm 10 mm 120 A Guard
£451.74
TO12S03-0104GC YMC-Triart C8 Guard Cartridge, 12nm, 3um, 10 x 4mm, 5pk C8 YMC-Triart C8 L7 3 um 4.0 mm 10 mm 120 A Guard
£451.74
TO12S03-02Q1GC YMC-Triart C8 Guard Cartridge, 12nm, 3um, 20 x 2.1mm, 5pk C8 YMC-Triart C8 L7 3 um 2.1 mm 20 mm 120 A Guard
£518.17
TO12S03-0203GC YMC-Triart C8 Guard Cartridge, 12nm, 3um, 20 x 3mm, 5pk C8 YMC-Triart C8 L7 3 um 3.0 mm 20 mm 120 A Guard
£518.17
TO12S03-0204GC YMC-Triart C8 Guard Cartridge, 12nm, 3um, 20 x 4mm, 5pk C8 YMC-Triart C8 L7 3 um 4.0 mm 20 mm 120 A Guard
£518.17
TO12S05-01Q1GC YMC-Triart C8 Guard Cartridge, 12nm, 5um, 10 x 2.1mm, 5pk C8 YMC-Triart C8 L7 5 um 2.1 mm 10 mm 120 A Guard
£451.74
TO12S05-0103GC YMC-Triart C8 Guard Cartridge, 12nm, 5um, 10 x 3mm, 5pk C8 YMC-Triart C8 L7 5 um 3.0 mm 10 mm 120 A Guard
£451.74
TO12S05-0104GC YMC-Triart C8 Guard Cartridge, 12nm, 5um, 10 x 4mm, 5pk C8 YMC-Triart C8 L7 5 um 4.0 mm 10 mm 120 A Guard
£451.74
TO12S05-02Q1GC YMC-Triart C8 Guard Cartridge, 12nm, 5um, 20 x 2.1mm, 5pk C8 YMC-Triart C8 L7 5 um 2.1 mm 20 mm 120 A Guard
£518.17
TO12S05-0203GC YMC-Triart C8 Guard Cartridge, 12nm, 5um, 20 x 3mm, 5pk C8 YMC-Triart C8 L7 5 um 3.0 mm 20 mm 120 A Guard
£518.17
TO12S05-0204GC YMC-Triart C8 Guard Cartridge, 12nm, 5um, 20 x 4mm, 5pk C8 YMC-Triart C8 L7 5 um 4.0 mm 20 mm 120 A Guard
£518.17
TO12SP9-10Q1PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 100 x 2.1mm C8 YMC-Triart C8 L7 1.9 um 2.1 mm 100 mm 120 A Column
£678.74
TO12SP9-1002PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 100 x 2mm C8 YMC-Triart C8 L7 1.9 um 2.0 mm 100 mm 120 A Column
£678.74
TO12SP9-1003PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 100 x 3mm C8 YMC-Triart C8 L7 1.9 um 3.0 mm 100 mm 120 A Column
£678.74
TO12SP9-15Q1PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 150 x 2.1mm C8 YMC-Triart C8 L7 1.9 um 2.1 mm 150 mm 120 A Column
£746.09
TO12SP9-1502PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 150 x 2mm C8 YMC-Triart C8 L7 1.9 um 2.0 mm 150 mm 120 A Column
£746.09
TO12SP9-1503PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 150 x 3mm C8 YMC-Triart C8 L7 1.9 um 3.0 mm 150 mm 120 A Column
£746.09
TO12SP9-02Q1PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 20 x 2.1mm C8 YMC-Triart C8 L7 1.9 um 2.1 mm 20 mm 120 A Column
£662.37
TO12SP9-0202PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 20 x 2mm C8 YMC-Triart C8 L7 1.9 um 2.0 mm 20 mm 120 A Column
£662.37
TO12SP9-03Q1PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 30 x 2.1mm C8 YMC-Triart C8 L7 1.9 um 2.1 mm 30 mm 120 A Column
£642.49
TO12SP9-0302PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 30 x 2mm C8 YMC-Triart C8 L7 1.9 um 2.0 mm 30 mm 120 A Column
£642.49
TO12SP9-0303PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 30 x 3mm C8 YMC-Triart C8 L7 1.9 um 3.0 mm 30 mm 120 A Column
£662.37
TO12SP9-05Q1PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 50 x 2.1mm C8 YMC-Triart C8 L7 1.9 um 2.1 mm 50 mm 120 A Column
£662.37
TO12SP9-0502PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 50 x 2mm C8 YMC-Triart C8 L7 1.9 um 2.0 mm 50 mm 120 A Column
£662.37
TO12SP9-0503PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 50 x 3mm C8 YMC-Triart C8 L7 1.9 um 3.0 mm 50 mm 120 A Column
£662.37
TO12SP9-0546PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 50 x 4.6mm C8 YMC-Triart C8 L7 1.9 um 4.6 mm 50 mm 120 A Column
£662.37
TO12SP9-L5Q1PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 75 x 2.1mm C8 YMC-Triart C8 L7 1.9 um 2.1 mm 75 mm 120 A Column
£662.37
TO12SP9-L502PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 75 x 2mm C8 YMC-Triart C8 L7 1.9 um 2.0 mm 75 mm 120 A Column
£662.37
TO12SP9-L503PT YMC-Triart C8 UHPLC Column, 12nm, 1.9um, 75 x 3mm C8 YMC-Triart C8 L7 1.9 um 3.0 mm 75 mm 120 A Column
£662.37
TO12SP9-E5Q1CC YMC-Triart C8 UHPLC Guard Cartridge, 12nm, 1.9um, 5 x 2.1mm, 3pk C8 YMC-Triart C8 L7 1.9 um 2.1 mm 5 mm 120 A Guard
£858.72
TO12SP9-E503CC YMC-Triart C8 UHPLC Guard Cartridge, 12nm, 1.9um, 5 x 3mm, 3pk C8 YMC-Triart C8 L7 1.9 um 3.0 mm 5 mm 120 A Guard
£858.72
TO12S05-R504PTH YMC-Triart C8 Column, 12nm, 5um, 125 x 4mm, PTH Hardware C8 YMC-Triart C8 L7 5 um 4.0 mm 125 mm 120 A Column
£695.10
  • Alternative to C18
  • Short retention time
  • pH stable 1 - 12
  YMC-Triart C8
Modification C8 (USP L7)
Particle size 1.9, 3, 5 µm
Pore size 12 nm / 120 Å
Surface area 360 m2/g
Carbon load 17%
Endcapping multi-stage
pH range 1 - 12
Temp range pH 1-7: 90°C
pH 7-12: 50°C
YMC Oligonucleotide Columns (12.94 MB)
Recommended YMC columns for oligonucleotide separations
YMC Analytical Phase Overview (244.31 kB)
For reversed phase HPLC and UHPLC
YMC Triart Brochure (23.66 MB)
Reliable, robust, reproducible (U)HPLC columns
YMC Triart Phase Overview (1.94 MB)
YMC Triart radar charts for column selection for method development
Copyright © 2023 Element Materials Technology